[ 15-24 ]
MZ870 / MZ890 / MZ1070 / MZ1090
(Revision 0.9)
TEST MODE
No.
Data setting
Print drum
changeover
0543
Master-clamp-range adjustment
B
Description Adjusts the master clamp range during master-loading.
Setting
Setting range: –100 to +100 (–10.0 mm to +10.0 mm) * (<+> to increase)
Setting unit: 1 (0.1 mm)
Default: 0 (0 mm)
0544
Master cut length adjustment
B
Description Adjusts the length of a single master (cutting timing).
Setting
Setting range: –100 to +100 (–10.0° to +10.0°)
Setting unit: 5 (0.5°) * (1°= approx. 1.5 mm, <+> for increased master length)
Default: 0 (0°)
0545
TPH Thermal Power Adjustment
–
Description Adjusts the TPH power.
Setting
Setting range: 0 to 8 * (Smaller the number the higher the TPH power)
Default: MZ8/MV8 = 2 MZ10/MV10 = 4
No.
Data setting
Print drum
changeover
0547
Master-making speed adjustment
B
Description
Regulates the speed of the write pulse motor to adjust image stretching/
shrinkage during master-making.
Setting
Setting range: –100 to +100 (–10.0% to +10.0%) * (<+> to elongate)
Setting unit: 1 (0.1%)
Default: 3 (0.3%)
0548
Write Roller Diameter Reference Adjustment
–
Description
Input the diameter of the Write roller to compensate the fluctuation in diameter
between the rollers.
Setting
Setting range:2305 (23.05mm) to 2315 (23.15mm)
* (input the diameter in millimeters x 100)
Setting unit: 1 (0.01mm)
Default: 2310 (23.10mm)
0550
Master-making Unit Adjustment
B
Description Adjusts the master-making unit stop position for master-making.
Setting
Setting range: –20 to +20 (–2.0 mm to +2.0 mm)
Setting unit: 1 (0.1 mm)
Default: 10 (1.0 mm)
0551
Master-making Unit Pull-Out Position Adjustment
–
Description Adjusts the master-making unit stop position for removal.
Setting
Setting range: –20 to +20 (–2.0 mm to +2.0 mm)
Setting unit: 1 (0.1 mm)
Default: 0 (0 mm)
0570
M.-Rmv. Roller Stop Timing
B
Description Sets the timing for vertical transport rollers to stop in relation to print drum angle.
Setting
Setting range: –50 to +50 (–50 degrees to +50 degrees)
Setting unit: 1 (1 degree)
Default: No.1 Drum = 0 (0 degree) No.2 Drum = 30 (30 degrees)
Summary of Contents for MZ1070
Page 2: ...MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 ...
Page 6: ... 2 6 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MACHINE SUMMARY MEMO ...
Page 16: ... 2 16 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MACHINE SUMMARY MEMO MACHINE SUMMARY ...
Page 24: ... 3 24 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MAIN DRIVE SECTION MEMO MAIN DRIVE SECTION ...
Page 32: ... 5 8 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 SECOND PAPER FEED SECTION MEMO ...
Page 38: ... 14 4 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 MASTER MAKING SECTION MEMO ...
Page 40: ... 15 6 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 TEST MODE MEMO ...
Page 86: ... 15 52 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 TEST MODE MEMO ...
Page 88: ... 16 54 MZ870 MZ890 MZ1070 MZ1090 Revision 0 9 PANEL MESSAGE MEMO ...