[ 14-3 ]
MZ870 / MZ890 / MZ1070 / MZ1090
(Revision 0.9)
MASTER MAKING SECTION
1. Pull out the Master making unit from the machine, turn OFF the machine power and disconnect the
power cord from the machine.
2. Open the Master making upper unit and remove the Cutter cover assembly.
3. Remove the Master positioning sensor cover. (1 screw)
4. Disconnect the connector, and remove the Master positioning sensor.
Removing the Master Positioning Sensor
Master positioning sensor cover
Master positioning sensor
Master positioning sensor cover
Master positioning sensor bracket
The mounting screw on this bracket must not be loosened.
The mounting position is set by a JIG at the factory.
DO NOT LOOSEN THIS SCREW !
Master positioning sensor bracket
The mounting screw on this bracket must not be loosened.
The mounting position is set by a JIG at the factory.