RIGOL
Chapter 4 Functions of the Front Panel of EMI
4-38 RSA3000E User Guide
Peak Config
1.
Peak Threshold
Specifies the minimum value of the peak amplitude. Only when the peak is
greater than the peak threshold, can it be judged as a peak.
Table 4-17 Peak Threshold
Parameter
Remarks
Default
16.99 dBuV
Range
-93.01 dBuV to 106.99 dBuV
Unit
dBm, dBmV, dBuV, V, W
Knob Step
1 dBuV
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5 dBuV
2.
Threshold State
Enables or disables the peak threshold function.
Remarks:
When the peak threshold function is enabled, press Peak Threshold to set
it.
When the peak threshold function is disabled, the Peak Threshold menu
is grayed out and disabled.
3.
Peak Excursion
Sets the excursion of the peak amplitude. It defines the minimum amplitude
variation required for a signal to be identified as peak.
Table 4-18 Peak Amplitude
Parameter
Remarks
Default
6 dB
Range
0 dB to 100 dB
Unit
dB
Knob Step
1 dB
Left/Right Arrow Key Step
Up/Down Arrow Key Step
5 dB
4.
Excursion State
Enables or disables the peak excursion function.
Remarks:
When the peak excursion function is enabled, press Peak Excursion to set
it.
When the peak excursion function is disabled, the Peak Excursion menu
is grayed out and disabled.