Start Aqua Condens 25/60 BIS
42
Start Aqua Condens 25/60 BIS
STORAGE TANK DESCRIPTION
UM
Storage cylinder type
Stainless steel
Storage cylinder arrangement
Vertical
Heat exchanger arrangement (coil)
Vertical
DHW content
60
l
Coil water content
3,87
l
Heat exchange surface
0,707
m²
Selection field of the DHW temperature
37-60
°C
Flow limiter
15
l/min
Quantity of water taken in 10’ with
∆
t 30°C
158,7
l
Storage cylinder maximum operating pressure
8
bar
Description
Methane gas (G20)
Propane (G31)
Lower Wobbe index (at 15°C-1013 mbar)
MJ/m
3
S
45,67
70,69
Net Calorific Value
MJ/m
3
S
34,02
88
Supply nominal pressure
mbar
mm H
2
O
20
203,9
37
377,3
Supply minimum pressure
mbar
mm H
2
O
10
102,0
Start Aqua Condens 25/60 BIS
Number of diaphragm holes
N°
1
1
Diaphragm holes diameter
Ø mm
6,7
4,7
Heating maximum gas capacity
Sm
3
/h
kg/h
2,64
-
-
1,94
DHW maximum gas capacity
Sm
3
/h
kg/h
2,64
-
-
1,94
Heating minimum gas capacity
Sm
3
/h
kg/h
0,63
-
-
0,47
DHW minimum gas capacity
Sm
3
/h
kg/h
0,63
-
-
0,47
Number of fan rotations with slow ignition
rpm
3.400
3.400
Maximum number of heating fan rotations
rpm
5.600
5.600
Maximum number of DHW fan rotations
rpm
5.600
5.600
Minimum number of heating fan rotations
rpm
1.700
1.700
Minimum number of DHW fan rotations
rpm
1.700
1.700
Seasonal space heating energy efficiency class
A
Water heating energy efficiency class
A
Parameter
Symbol
Value
Unit
Parameter
Symbol
Value
Unit
Rated heat output
Prated
25
kW
Seasonal space heating energy
efficiency
η
s
92
%
For boiler space heaters and boiler combination heaters: useful heat output
For boiler space heaters and boiler combination heaters: useful efficiency
At rated heat output and high-
temperature regime (*)
P4
24,5
kW
At rated heat output and high-
temperature regime (*)
η
4
88,8
%
At 30% of rated heat output and low-
temperature regime (**)
P1
8,0
kW
At 30% of rated heat output and low-
temperature regime (**)
η
1
96,4
%
Auxiliary electricity consumption
Other parameters
At full load
elmax
50,0
W
Stand-by heat loss
Pstby
58,0
W
At part load
elmin
16,7
W
Pilot flame energy consumption
Pign
-
W
In Stand-by mode
PSB
2,4
W
Annual energy consumption
QHE
48
GJ
Sound power level, indoors
LWA
54
dB
Emissions of nitrogen oxides
NOx
27
mg/
kWh
For combination heaters:
Declared load profile
XL
Water heating energy efficiency
η
wh
81
%
Daily electricity consumption
Qelec
0,302
kWh
Daily fuel consumption
Qfuel
24,057
kWh
Annual electricity consumption
AEC
66
kWh
Annual fuel consumption
AFC
18
GJ
(*) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature at heater outlet.
(**) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for other heaters 50 °C return temperature (at heater inlet).
Summary of Contents for Start Aqua Condens 25/60 BIS
Page 73: ...Start Aqua Condens 25 60 BIS 73 22 23 24 1 2 3 4 5 25 F A G B C A D E...
Page 74: ......
Page 75: ......
Page 76: ...Cod 20114812 03 16 Ed 0...