Start Aqua Condens 25/60 BIS
40
BOILER STATUS
DISPLAY
TYPE OF
ALARM
Calibration service
ADJ
Signal
Calibration installer
Chimney sweep
ACO
Signal
Vent cycle
Signal
External probe presence
Signal
Domestic water heat request
60
°C
Signal
Heating heat request
80
°C
Signal
Antifreeze heat request
Signal
Flame present
Signal
J - Resetting the faults
To restore operation (reset alarms):
Faults A01-02-03
Turn the mode selector to
OFF, wait 5-6 seconds, then return the
selector to the required position.
If the reset attempts do not reactivate the boiler, request the interven-
tion of the Technical Assistance Centre.
Fault A04
In addition to the fault code, the digital display displays the symbol
.
Check the pressure value indicated by the water gauge:
if it is less than 0.3 bar, position the function selector on
OFF and
adjust the filling tap until the pressure reaches a value between 1
and 1.5 bar.
filling tap
Then turn the mode selector to the required position. The boiler will
carry out a venting cycle lasting about 2 minutes.
If pressure drops are frequent, request the intervention of the Tech-
nical Assistance Centre.
Fault A06
The boiler functions normally but does not guarantee a constant do-
mestic hot water temperature, which remains set at around 50°C.
The intervention of the Technical Assistance Centre is required.
Fault A07-A 08
Contact the Technical Assistance Centre.
Fault A09
Turn the mode selector to
OFF, wait 5-6 seconds, then return the
selector to the required position.
If the reset attempts do not reactivate the boiler, request the interven-
tion of the Technical Assistance Centre.
Fault A77
The fault is self-resetting, if the boiler does not restart contact the
Technical Assistance Centre.
K - Regular scheduled maintenance
OPERATIONS
1st
YEAR
2nd
YEAR
Inspection of sealing components
°
°
Cleaning of the primary heat exchanger flue gases side
°
°
Cleaning of the combustion chamber,
fan and venturi tubes
°
°
Checking of the water and gas safety devices
°
°
Checking the gas output and make any adjustments
°
°
Checking the draught and flue gases pipe
°
°
Cleaning of the burner and checking its firing
°
°
Checking the hydraulic operations
°
°
Combustion analysis
-
°
Checking and lubricating the hydraulic unit components
-
°
Checking the system seals
-
°
Washing of the heat exchanger
-
°
Checking the efficiency of the electric
and electronic components
-
°
FAN EFFICIENCY (only for vacuum chamber versions)
°
°
Checking the condensate discharge system
°
°
CHECKING THE CONDENSATE
NEUTRALISER (if installed)
°
°
NOTE:
the maintenance operations described above, must be car-
ried out every two years in accordance with regulations in force.
L - Cleaning
The only cleaning operations that we recommend are those involving
the external boiler panels, which should be cleaned using just a cloth
dampened with soap and water.
In the case of stubborn marks, dip the cloth in a mixture of 50% water
and methylated spirits, or use specific products.
Do not use fuels and/or sponges soaked in abrasive solutions
or powder detergents.
It is forbidden to carry out any cleaning operations before dis-
connecting the boiler from the mains electricity supply; to do
this, turn the main system switch to “off”.