A - General warnings
This booklet, along with those for the installer and the Technical
Assistance Centre, is an integral part of the boiler and must
therefore be kept in a safe place. They must always be passed
on with the boiler if this is transferred to another owner/user or
to another system. If they are damaged or lost, another copy
must be requested from your local Riello Technical Assistance
Centre.
The installation of the Family Aqua Condens 3.5 BIS boiler
must be performed by a qualified company that will issue the
owner with the installation conformity declaration on comple-
tion of the work, in compliance with the applicable National and
Local Standards and the instructions supplied by Riello in the
instruction booklet supplied with the appliance.
The boiler must be used for the purpose envisaged by Riello,
for which it was expressly made.
No liability will be accepted, within or outside the contract, by
Riello for any harm to people,animals or property caused by
installation, adjustment or maintenance errors, or by improper
use.
In the event of a water leakage, shut off the water supply and
promptly contact the Riello Technical Assistance Centre or oth-
er professionally qualified personnel.
Check the display regularly to make sure the
icon (indicating
an incorrect priming pressure) does not light up.
If this icon is illuminated, contact the Riello Technical Assis-
tance Centre or other professionally qualified personnel.
If the boiler is not used for a long time, the following operations
must be carried out:
- press
. The display will visualise the words “ENERGY
FOR LIFE” and the anti-freeze icon;
- set the system's main switch to "off";
- turn off the fuel and water taps of the heating and domestic
hot water system;
- drain the heating and domestic water system if there is any
risk of freezing.
The circulator anti-locking function is activated after 24 hours of
non-use, with the mode selector in any position.
For installation, it is advisable to contact specialised personnel.
At the end of its life, the product should be not be disposed of
as solid urban waste, but rather it should be handed over to a
differentiated waste collection centre.
B - Basic safety rules
Remember that the use of products requiring fuels, electricity and
water necessitates the respect of certain basic safety rules such as:
It is forbidden for children and unassisted unskilled people to
use the boiler.
It is forbidden to activate electric devices or appliances such as
switches, household appliances and so on if you notice a smell
of fuel or unburned fuel. In this case:
- ventilate the room by opening the doors and windows;
- close the fuel shut-off device;
- promptly contact the Technical Assistance Centre or other
professionally qualified personnel.
It is forbidden to touch the boiler while barefoot or if parts of
your body are wet.
It is forbidden to carry out any cleaning operations before dis-
connecting the boiler from the electricity supply; to do this, turn
the main system switch to “OFF”.
It is forbidden to pull, detach or twist the electric cables that
emerge from the boiler, even if the boiler itself is disconnected
from the mains supply.
It is forbidden to plug or reduce the size of any openings used
for airing the installation area.
It is forbidden to leave flammable containers and substances in
the room where the boiler is installed.
It is forbidden to place any objects on the boiler, as they could
be a source of danger.
It is forbidden to disconnect the boiler from the electricity sup-
ply and close the gas tap if there is a risk of the temperature
falling below zero, as the 1st level antifreeze system (protec-
tion up to -3°C) would be disabled.
It is forbidden to intervene on sealed elements.
It is forbidden to obstruct the condensate outlet.
C - Commissioning
The boiler should be started up for the first time by the Technical
Assistance Centre after which the boiler will be able to operate auto-
matically. It may, however, be necessary to restore boiler operation
without contacting the Technical Centre: for example after a lengthy
period of absence.
In such cases, the following checks and operations must be carried
out:
- Make sure the fuel and water taps of the heating system and the
domestic water system are open.
- Check the operating condition of the consumption water filtering
and/or treatment appliances.
- Each time the boiler is electrically powered, it begins an automatic
venting cycle that lasts about 2 minutes. The display will simultane-
ously show: 43 and
. Press the
key to interrupt the automatic
venting cycle.
If the check is correctly terminated, the boiler will be ready to operate
at the end of the automatic venting cycle.
The boiler switches back on in the status it occupied before switch-
off.
If the boiler was in the heating function when it was switched off, it will
switch back on in that function. If it was OFF, the display will visualise
the words ENERGY FOR LIFE.
Press the
key to activate operation.
- On the digital display check that the pressure of the cold hydrau-
lic circuit is always between 1 bar and 1.5 bar.