Family Aqua Condens 3.5 BIS
14
ENGLISH
15
1. Display only of the icon
The appearance of the
icon indicates that an operation fault has
been diagnosed and the boiler will attempt to resolve it autonomously
(temporary stop).
If the boiler does not resume normal operation, there are two possi-
ble display cases.
Case A
disappears, and the RESET icon appears along with a different
alarm code.
In this case, proceed as described in point 2.
CASE A
temporary
fault
definitive
fault
Case B
the RESET icon will appear along with a different alarm code, togeth-
er with the
.
In this case, proceed as described in point 3. In this case, proceed
as described in point 2.
CASE B
temporary
fault
definitive
fault
Case C
Together with the
, alarm code 91 will appear (see description be-
low).
The intervention of the Technical Assistance Centre is required.
The boiler is equipped with an auto-diagnostic system which, based
on the total number of hours in certain operating conditions, can sig-
nal the need to clean the primary exchanger (alarm code 91).
Once the cleaning operation has been completed, reset to zero the
total hour meter with special kit supplied as an accessory following
procedure indicated below:
- Switch off the power supply
- Remove the electric casing by means of the screws and fixing
hooks
- Extract the connector J13 (see wiring diagram)
- Power up the boiler and wait for alarm 13 to appear on the display
- Disconnect the power supply and reconnect connector J13
- Refit the electric casing and restore the boiler's function.
NOTE: the meter resetting procedure should be carried out after
each in-depth cleaning of the primary exchanger or if this latter is
replaced.
2. Display only of the RESET icon
Press the
key to restore operation. If the boiler performs the fir-
ing procedure and resumes normal operation, the stoppage can be
attributed to a chance situation.
Repeated lockouts require the intervention of the Riello Techni-
cal Assistance Centre.
3. Display of the RESET and
icons
The intervention of the Riello Technical Assistance Centre is required.
Fault on DHW circuit probe - 60
The fault code is only displayed in standby.
Fault J0 (card/interface connection): check that the electrical con-
nections are correct. If the fault persists after the control, contact the
Riello Technical Assistance Centre.
Fault J1 (without card/remote control panel connection): to re-
store the operation, press key
again and then key
until the
normal operation is restored.
Code
Fault description
RESET
icon
Icon
10
FLAME FAILURE LOCKOUT (D)
YES
NO
11
PARASITE FLAME (T)
NO
YES
12
NEW ATTEMPT IN PROGRESS (T)
NO
NO
13
MINIMUM GAS INPUT PRESSURE (T)
NO
YES
14
MINIMUM GAS INPUT PRESSURE (D)
YES
NO
20
LIMIT THERMOSTAT (D)
YES
NO
21
FLUE GAS PROBE SHORT CIRCUIT (D)
YES
YES
24
DELIVERY PROBE LIMIT TEMPERATURE (D)
YES
NO
25
DELIVERY PROBE LIMIT TEMPERATURE (T)
NO
YES
26
RETURN PROBE LIMIT TEMPERATURE (D)
YES
NO
27
RETURN PROBE LIMIT TEMPERATURE (T)
NO
YES
28
RETURN-DELIVERY PROBE
DIFFERENTIAL (D)
YES
YES
29
FLUE GAS PROBE OVER-
TEMPERATURE (D)
YES
YES
34
FAN (cycle start) (D)
YES
NO
37
FAN CYCLE IN PROGRESS (high rpm) (D)
YES
YES
40
INSUFFICIENT SYSTEM PRESSURE (D**)
YES
NO
41
INSUFFICIENT SYSTEM PRESSURE (T**)
NO
YES
42
WATER PRESSURE TRANSDUCER (D)
YES
YES
50-59
ELECTRONIC CARD (D)
YES
YES
60
DHW PROBE 1 (T) (°)
NO
YES
65
MINI-ACCUMULATION ALARM
(NOT DISPLAYED ON THIS MODEL)
YES
YES
70
PRIMARY PROBE SHORT
CIRCUIT/OPEN (D)
YES
YES
71
DELIVERY PROBE OVER-
TEMPERATURE (T)
NO
NO
72
RETURN PROBE SHORT CIRCUIT/OPEN (D)
YES
YES