45
Update Rate
➥
Display
Regarding measured values, Voltage, Current, Power, Etc.
LOW
Average value of the last 6 measurements
MEDIUM
Average value of the last 3 measurements
HIGH
Value of most recent measurement only
Options DO NOT affect measurement accuracy
Options available to smooth measurement Jitter, for readability only.
USB Interface
➥
Communication
Selectable Options:
OFF / 9600 / 19200 / 38400 / 57600 / 115200
Selects the Baud Rate for use with the Front Panel Micro-USB connector.
When enabled, a USB icon will be displayed at the top of the screen:
UVP
(Under Voltage Protection)
➥
Power Settings or Quick Setting Menu (
“
SHIFT
” + “
▼
”)
Value
Minimum allowable output Voltage, during normal operation
IF
the Voltage falls below the set value:
● Unit will enter
● The output will immediately turn OFF.
● The
“
ON/OFF
”
button will turn off its illumination,
○ or react per the setting of ‘
’.
● The
indicator is replaced by a red background with a
white ‘UVP’ Icon.
Notes:
-
Disabled by setting to
0
.
-
Protection is not enabled until the Voltage has stopped rising for at least 500ms.
-
The PC Software and Smartphone App from Ruideng DO NOT Recognize this error.
IF
the RD60xx enters Protection mode due to UVP:
Connected (Riden) Software, using any interface (USB, UART), will report
an ‘
’ Error.