20
CutOff -dV/dT
➥
Battery Charger
OFF
NOT monitoring for voltage drop during charging.
Value
Set in
0.01
V steps.
IF
Set,
● If, 5 minutes after the output is turned on, the voltage drops by more than the specified
value, the output will be disabled with the "-dV/dT" status.
● If no voltage rise is detected within 15 minutes, the output will be turned off with the
"0dV/dT" status.
Notes:
-
This setting is only applicable using the (Green) Battery Charging Binding post.
-
To be used for Ni based chemistries (NiMh/NiCd).
-
Experimental use only, may not work correctly due to the low ADC resolution.
-
Algorithm taken from
.
CutOff cap.
➥
Battery Charger
OFF
NOT monitoring for total capacity charged while battery charging.
Value
Set in
0.001
Ah steps.
IF
Set,
Battery charging cycle will halt once the set value is achieved.
Note:
This setting is only applicable using the (Green) Battery Charging Binding post.
CutOff current
➥
Battery Charger
Value
Set in
10mA
steps.
Charging current where the RD60xx unit will consider the battery ‘Full’.
(Charging cycle will halt.)
Note:
This setting is only applicable using the (Green) Battery Charging Binding post.