42
Timer Mode
{CS Menu}
OFF
Output Timer is NOT enabled.
Single
Output ON/OFF will go through ‘
’ and ‘
’ once.
Cyclic
Output ON/OFF continuously cycles through ‘
’ and ‘
’,
IF
‘
’ is set to
00 00 00
, Timer Mode will not do anything.
IF
set to
Single
, will need to be re-enable after each use.
Notes:
Timers start when the
“
ON/OFF
”
Button is pressed, unless ‘
’ is
enabled.
Changing the ‘Timer Mode’ settings while the output is ON may result in
unexpected behaviour.
Setting is automatically disabled on power-down.
Timer Off
{CS Menu}
Settable Range:
00 00 00 - 99 59 59
(Hours, Minutes, Seconds)
IF
Set to
00 00 00
, ‘
’ will not activate.
IF
Timer Mode active:
When value reaches
00 00 00
, output will turn OFF.
IF
‘
’ is set to
00 00 00
,
When ‘
’ expires:
Output will turn OFF.
The
indicator is replaced by a white on red
background ‘TIME’ icon.
Timer On
{CS Menu}
Settable Range:
00 00 00 - 99 59 59
(Hours, Minutes, Seconds)
IF
Timer Mode active:
After
’ expires and the output is turned OFF.
‘Timer On’ will then start counting down.
When ‘Timer On’ expires, the output will turn back ON.