the inrush lasts less than the Delay time and then falls below the
value, the unit
will continue to operate like a normal
only Power Supply.
However,
IF
the current draw climbs back above the OCP value:
● The RD60xx will
NOT
go into
● The RD60xx
WILL
go into
after the response delay
Special Notes:
-
This option is for
ADVANCED USERS ONLY
.
-
Improper use
could result in Equipment or Personal Damage
.
-
Ensure you understand how this option works before use.
-
To enable this option, the ‘
ON-CODE
’ value MUST be set to
11235
.
(Hint to remember the code:
Fibonacci Sequence
)
Any
other value will result in the option being set to
OFF
.
-
On Testing, the Delay is
typically
around 250ms, but has been measured up to
600ms.
IVSet Timeout
➥
Appearance
OFF:
IVSet Timeout is NOT enabled.
Settable Range:
00m 01s - 99m 59s
Determines if, and for how long, the unit will wait for data entry when setting a value using the
“
I-SET
” or “
V-SET
” buttons.
This applies for setting the Voltage, Current, OVP, OCP, or OPP values.
IF
Set:
● The timer will reset on any data entry, except “
ENTER
”.
○ Pressing “
ENTER
” will apply the current setting.
● The value displayed at the end of the timeout timer will automatically be applied.
Key Beep
➥
Buzzer
ON
Buzzer sounds once when any button(s) is pressed.
OFF
Buzzer does NOT sound when button(s) pressed.
LOCK
Can Only be Enabled by Panel buttons
“
SHIFT
” + “
●
”
When enabled, physical buttons and encoder knob have no affect.