5.9 Change Direction-of-rotation - Switching sense
If necessary, it is possible to change the direction-of-rotation and/or the switching sense. Refer to
§6.2, §7.2 and §7.3.
Wiring diagram §5.5–5.6 [RLS]: RW45\RW241/242
Wiring diagram §5.7–5.8 [RSU]: RW243/245/400/600\RW800\RW70/140
5.10 OPTIONAL - Position Feedback
You can connect a digital positioning-meter (
RPU
) or a Ridder
Potentiometer
installation set to the
RW motor-gearbox. Refer to the product-manuals at
for the installation and connections.
6. USER INSTRUCTIONS
If work becomes necessary when you use the drive unit (normal operation),
approved personnel
usually must do the work.
6.1 Usage - Conditions and starting points
The conditions and starting points that follow are applicable when you use the RW motor-gearbox.
Automatic Control
Change direction-of-rotation:
Interchange V1 and W1 on the terminal block (EM).
Change switching sense:
Interchange 1 and 5 of the RLS.
Change direction-of-rotation:
Interchange V1 and W2 on the terminal block (EM).
Change switching sense:
Interchange 1 and 7 of the RSU.
The motor can start and stop automatically without a warning.
Persons can be in danger of life if they touch a system that is in
operation.