7.4 Setting the end positions
u
Description
1
Connect the tube motor to the adjusting switch.
2
Push the related Up-Down button and let the tube
motor turn to a top end-position or a bottom end-
position.
3
Push the programming button for a minimum of 3
seconds. The end position is set after the tube motor
gives one “click”.
Click
4
Push the related Up-Down button and let the tube
motor turn to the other end position.
The first selected direction after step 3 is immediately set.
Make sure that this direction is correct for the second end
position. If the selected direction is incorrect, erase the first
end position (refer to §7.5) and do the procedure again.
5
Push the programming button for a minimum of 3
seconds. The end position is set after the tube motor
gives one “click”.
Click
At this time the limit-switch system and the range of travel of the RB50Eᵖˡᵘˢ tube motor are set.
Disconnect the tube motor from the adjusting switch. Connect the tube motor to the control box.