5/10/99 SMA0001A.PDF 1-6
In-Floor Ramp Controller
11584
Connectors from Single Harness Controller to In-Floor Ramp Controller
J11-4 Pin
Connector
DB9-9 Pin
Connector
Wire
Color
Function At Rest In Action
2
3
4
7
8
9
J10-10 Pin
Connector
Amp 10
Pin
Connector
Wire
Color
Functions At Rest In Action
1-
Ramp Controller
12 Volts* 12 Volts
2-
Ramp Controller
12 Volts* 12 Volts
3-
Ramp Controller
Ground Ground
4-
Ramp Controller
Ground Ground
5-
Deploys; Tied with
other ROM wire
12 Volts Pulsed ground when motor
stows ramp (LED RO** will
light during action)
6-
Deploys; Tied with
other ROM wire
12 Volts Pulsed ground when motor
stows ramp (LED RO** will
light during action)
7-
Tied with other RCM
wire
12 Volts Pulsed ground when motor
stows ramp (LED RC** will
light during action
8-
Tied with other RCM
wire
12 Volts Pulsed ground when motor
stows ramp (LED RC** will
light during action
9-
DCLE
is fully Stowed for
door operation
Fully Stowed:
Ground
Partially Deployed: none
10-
RSI
10
Red Ramp Stowed
Sensor Power
Supply
12 Volts to
Ramp
Stowed
Sensor
12 Volts to Ramp Stowed
Sensor
*If Supplemental Relay is disconnected, then the Single Harness Controller should have constant
12 volts power. This should supply the fuse at
F2
to supply the In-Floor Ramp Controller a
constant 12 volts on terminals
VCC
at
J10
.
**These LED’s are located on the Single Harness Controller.