5/10/99 SMA0001A.PDF 1-9
travel. The setting should be as high as possible and still accomplish current limit at end-of-
travel.
A. Locate STOW ADJUSTMENT SCREW.
B. Using a screwdriver, turn adjustment screw
CCW
until it stops (do not force). Ramp is
now set for highest current limit, causing motor to stall instead of unit shutting down.
C. Stow ramp. Keep function selected after ramp has reached end-of-travel.
D. While holding STOW function, turn adjustment screw
CW
until an audible “click” is
heard. This indicates current limit has been triggered.
E. Adjust screw an additional
1/16 turn CW
.
F. Deploy ramp approximately 6 inches (15-16 cm.).
G. Fully stow ramp and observe ramp pull against enclosure back-stop then visibly “relax” as
current limit shuts off power to motor.