5/10/99 SMA0001.PDF 1-20
J7 Name on Board Wire Color Function At Rest In Action
Folding Ramp
Ground
Folding Ramp
12V when motor
deploys ramp (LED
RO
will light during
action)
ROM
White Ramp motor
deploys; Tied
with other
ROM wire
In-Floor Ramp
12 volts
In-Floor Ramp
Pulsed Ground (LED
RC
will light during
action)
Folding Ramp
Ground
Folding Ramp
12V when motor
deploys ramp (LED
RO
will light during
action)
ROM
White Ramp motor
deploys; Tied
with other
ROM wire
In-Floor Ramp
Ground
Folding Ramp
12V when motor
deploys ramp (LED
RO
will light during
action)
*To accurately measure switch, it is necessary to place ramp in desired position. Then unplug
harness and check for continuity. Failure to remove plug will give inaccurate reading and may
possibly allow for erroneous door or ramp operation.
**Ramp may be manually swung away by depressing yellow lever. Doing so will allow door to
rotate on the opposite axis. Ramp must be completely shut to allow for power operation.
i
CAUTION
J10
AND
J11
ARE USED TO CONNECT THE IN-FLOOR CONTROLLER. THESE
TERMINALS WILL ONLY BE USED IN THE PRESENCE OF AN IN-FLOOR RAMP. DO NOT
CONNECT AN IN-FLOOR CONTROLLER, 11584, TO A SINGLE HARNESS CONTROLLER
WITH RELAYS INSTALLED ON SOCKETS
K2
AND
K4
. DO NOT INSTALL RELAYS INTO
SOCKETS
K2
AND
K4
IF THE SINGLE HARNESS CONTROLLER IS CONNECTED TO AN
IN-FLOOR RAMP CONTROLLER