5/10/99 SMA0001A.PDF 1-7
LED’s
NOTE
IF THE SUPPLEMENTAL RELAY BYPASS IS CONNECTED, THE LED’s WILL ONLY
ILLUMINATE WHILE A SWITCH IS DEPRESSED OR THE VEHICLE IS KNEELING.
OTHERWISE POWER WILL BE REMOVED FROM THE SINGLE HARNESS CONTROLLER
AND IN-FLOOR CONTROLLER.
In-Floor Ramp Controller
11584
Label Color Function
Stow Green When the system is powered up, the Stow LED will
illuminate when the ramp is fully stowed
Close Amber The LED will illuminate while the system is providing power
to stow the ramp
Open Amber The LED will illuminate while the system is providing power
to deploy the ramp
Pwr Out Green Indicates that the In-Floor Controller is completely powered
up; the In-Floor Controller will stay fully powered up for
approximately 60 seconds; then it will go into standby
mode
i
CAUTION
THE IN-FLOOR RAMP CONTROLLER IS ADJUSTED AT THE TIME OF INSTALLATION. IT
SHOULD NOT EVER NEED TO BE ADJUSTED. THE ONLY TIME IT SHOULD BE ADJUSTED
IS AFTER THE REPLACEMENT OF A RAMP COMPONENT (I.E. RAMP MOTOR, NEW IN-
FLOOR CONTROLLER, ETC.)
In-Floor Ramp Controller Adjustment
The purpose of ramp controller adjustment is to ensure ramp mechanism reliabilty in all operating
conditions while maintaining a margin of safety in event of blockage of ramp. In accordance with
this requirement, the ramp should be set to highest possible current setting that will not cause
personal injury in event of a blockage.
NOTE
THERE ARE TWO DIFFERENT TYPES OF IN-FLOOR RAMP CONTROLLERS IN REGARD TO
ADJUSTMENT. ONE IN-FLOOR RAMP CONTROLLER HAS WHITE PLASTIC ADJUSTMENT
SCREWS AND THE OTHER HAS BRASS ADJUSTMENT SCREWS.