5/10/99 SMA0001A.PDF 1-15
Power Ramp Harness
J7 Name on Board Wire Color Function At Rest In Action
FRCS
Brown/
Orange
Signals when
ramp is
Deployed
Fully Stowed:
Ground
Partially Deployed:
Ground
DCLE
Brown Signals when
ramp is fully
Stowed to allow
for door
operation
Fully stowed:
Ground
Partially Deployed:
none
RSI
Green Ramp Stowed
Sensor power
12 Volts to
Ramp Sensor
12 Volts to Ramp
Sensor
GSS
Red/Black Grounded input
to allow for
ramp operation
Ground Ground
RCM
Black Ramp motor
stows; Tied
with other RCM
wire
12 Volts Pulsed ground
when motor stows
ramp (LED
RO
will
light during action)
RCM
Black Ramp motor
stows; Tied
with other RCM
wire
12 Volts Pulsed ground
when motor stows
ramp (LED
RO
will
light during action)
ROM
White Ramp motor
deploys; Tied
with other ROM
wire
12 Volts Pulsed ground
when motor stows
ramp (LED
RC
will
light during action)
ROM
White Ramp motor
deploys; Tied
with other ROM
wire
12 Volts Pulsed ground
when motor stows
ramp (LED
RC
will
light during action)
*To accurately measure switch, it is necessary to place ramp in desired position. Then unplug
harness and check for continuity. Failure to remove plug will give inaccurate reading and may
possibly allow for erroneous door or ramp operation.
**Ramp may be manually swung away by depressing yellow lever. Doing so will allow door to
rotate on the opposite axis. Ramp must be completely shut to allow for power operation.
Fuses
Function Fuse Type Fuse Rating
F1
Not in use Not in use Not in use
F2
In-Floor Ramp
Controller
ATC blade type automotive 20 Amp
F3
Door Open and Folding
Ramp
ATC blade type automotive 20 Amp