80
Rigel-PJ1nx Training
Slide 80
Writing Data to New Boards
Data Writing After Replacing the Main Board – 14
Select ‘Floor’.
Display the Red raster signal by clicking ‘Test R’ in the Test Pattern box.
Adjust the R-scroll bar so that the flicker in the middle of the window
becomes as small as possible.
Do the same for Test G, then Test B.
When the adjustment is done, click ‘Set’ to write the new value to the
projector
If you need to restore the data to the state before the adjustment, click the
‘Reset’ button.
Select ‘Ceiling’ and repeat the procedure.
Chiral: Do not adjust
The values displayed by the side of each scroll bar show the original value to the
left of the arrow, and the current value to the right of the arrow.
If there are horizontal lines on the screen that prevent flicker from being seen
clearly, click the Test R, G or B button a few times until they go away.
Chiral adjustment: Do not use (the configuration of the LCD panels is always
LRL)