75
Rigel-PJ1nx Training
Slide 75
Writing Data to New Boards
Data Writing After Replacing the Main Board - 9
Set the Baud rate as shown above.
The Baud rate must be the same as the Baud rate setting on the projector
(Menu button – Setup – Installation – Communication Speed).
Input the serial number and model name in the following format, using
asterisks and spaces as shown.
* modelname serialnumber*
Click ‘Write’
No verification is performed, so click ‘Read’ after writing is finished, to
make sure that the projector got the data correctly.
Input serial number and
model name here