Technical Bulletin
No. RTB-011
SUBJECT: Original side to side registration
DATE: 15 Aug. ’91
PAGE: 1 of 5
PREPARED BY: J. Kasamoto
CHECKED BY:
FROM: Copier Technical Support Section
CLASSIFICATION:
Action Required
Troubleshooting
Retrofit Information
Revision of service manual
Information only
Other
MODEL:
F40 (RDH)
1. Replacement of the original table and side fences for machines produced before
June ’91.
Replacement procedure
1. Remove the RDH front [A] and rear [B]
covers (5 and 5 screws).
2. Open the left cover [C] by pushing the
release lever button.
3. Remove the feed-in unit top cover [D] (4
screws).
4. Remove the original stopper solenoid [E]
with the bracket on (1 screw), but do not
let the solenoid hang down by the
harness.
5. Remove the release lever unit [F] (2
screws and 2 springs). The springs may
suddenly release so be careful not to lose
the springs.
6. Remove the original stopper unit this way
(1 screw and 1 stud);
As in figure 2, first remove the front side
screw, then loosen the stopper pin [G].
After loosening the rear stud screw, lift up
the front side of the original stopper unit
[H] and unsecure the stud screw [I].
Remove the tension spring from the
spring anchor.
7. Remove the original entrance guide
assembly [J] (4 screws), and be careful
not to damage the harness and the
mylars.
Fig. 1
[A]
[D]
[C]
[F]
[E]
[B]
[G]
[I]
[H]
Fig. 2
[J]