Technical Bulletin
No. RTB-012
SUBJECT: 1. Additional steps for scanner wire replacement
2. Troubleshooting for SC21
DATE: 15 Aug. ’91
PAGE: 1 of 2
PREPARED BY: J. Kasamoto
CHECKED BY:
FROM: Copier Technical Support Section
CLASSIFICATION:
Action Required
Troubleshooting
Retrofit Information
Revision of service manual
Information only
Other
MODEL:
F40
Additional steps are needed in the service manual’s scanner wire replacement procedure.
Troubleshooting information relating to these steps is explained after.
1. Additional Steps
1-1 First, before reinstalling the wire (service manual P5-14, step 7), make sure of the
following.
•
Bring the cushion [A] to the side that has the larger hook.
•
The end that has the larger hook and the cushion, will connect to the spring as in
figure 1.
1-2 Add these steps to the service manual P5-15, immediately following step 12.
•
Loosen the 2 screws on the cushion holder [C]. Pull the holder towards the pulley
as far as it will go ([D]: direction) as in figure 2. Tighten the screws temporarily.
[B]
[A]
Fig. 1
[D]
[C]
Fig. 2