Technical Bulletin
No. RTB-011
SUBJECT: Original Side to Side Registration
DATE: 15 Aug. ’91
PAGE: 5 of 5
7. Loosen four screws [A] on the original table and adjust the side registration as shown
in figure 9. If case 2, follow procedure a. If case 3, follow procedure b.
a) Case 2:
The copy image has moved up. Measure the difference and adjust the
tray’s position by pulling it away from the RDH pedestal [B-direction].
Make sure the adjustment matches the difference.
b) Case 3:
The RDH copy image has moved down. Measure the difference and
adjust the tray’s position by pushing it towards the RDH pedestal
[C-direction]. Make sure the adjustment matches the difference.
8. Reassemble the document feeder.
9. Repeat the procedure from step 3. (Until both copies are identical.)
[C]
[C]
[B]
[B]
Fig. 9
[A]