Detailed Descriptions
117
D124
Temperature/Humidity Sensor
The temperature/humidity sensor [B] is mounted on the right side of the machine
above the ink supply unit. The machine uses the readings of the
temperature/humidity sensor to set the duty for operation of the ink cartridge pump
motors.
Ink is pumped to the sub tanks in very small increments, and the operation of the
ink pumps must be regulated to assure that the ink supply is constant.
Adjustments must be made to compensate for the expansion and contraction of
the ink tubes and other parts of the ink supply system caused by fluctuation in
temperature.
The readings of the K2 print head thermistor and the temperature/humidity sensor are
used together to calculate the operating temperature of the machine.
If the machine overheats and the operating temperature exceeds the maximum
temperature, the machine will shut down automatically and will not restart until it
has cooled and been cycled off/on. The machine must be cycled off/on, even after
it has cooled down to the operational range.
If the temperature is too low at a cold start in the morning, for example, the
machine will not start the initial cleaning cycle unit the machine has warmed up.
In this case, the machine does not require cycling off/on. The initial cleaning will
start as soon as the machine has warmed up, and then the machine is ready for
operation.
Summary of Contents for D124
Page 1: ...D124 DETAILED DESCRIPTIONS MANUAL ...
Page 2: ......
Page 20: ...D124 14 Detailed Descriptions 1 2 GENERAL LAYOUT ...
Page 24: ...D124 18 Detailed Descriptions 1 4 MOTORS CLUTCHES AIR RELEASE SOLENOID ...
Page 28: ...D124 22 Detailed Descriptions 1 6 ORIGINAL PATH PAPER PATH SENSORS ...
Page 62: ...D124 56 Detailed Descriptions 3 1 2 SCAN JOB IMAGE DATA FLOW 3 1 3 PRINT JOB IMAGE DATA FLOW ...