SERVICE CALL CONDITIONS
B234/B235/B236/D101/D102/D103
4-96
SM
Main Grip Open/Close Sensor: Front (S51,S53) Errors
The front main grip open sensor did not
go ON within the prescribed time after
the front grip motor turned on to open
the main grip unit.
-or-
The front main grip open sensor did not
go OFF within the prescribed time after
the front grip motor turned on to close
the main grip unit.
•
Grip Motor: Front (M24)
defective
•
Main Grip Open Sensor: Front
(S51) defective
•
Sensor or motor connector
loose, broken, defective
SC798-21
B
The front main grip close sensor did
not go ON within the prescribed time
after the front grip motor turned on to
close the main grip unit.
-or-
The front main grip close sensor did
not go OFF within the prescribed time
after the front grip motor turned on to
open the main grip unit.
•
Grip Motor: Front (M24)
defective
•
Main Grip Close Sensor: Front
(S53) defective
•
Sensor or motor connector
loose, broken, defective
Main Grip Encoder: Front Sensor (S52) Error
SC798-22
B
The front main grip encoder sensor
could not be detected ON/OFF
within the prescribed time after the
front grip motor turned on to
open/close the main grip unit.
•
Main Grip Encoder: Front Sensor
(S52) defective
•
Grip Motor: Front (M24) defective
•
Main Grip Encoder: Front Sensor
(S52) defective
•
Sensor or motor connector loose,
broken, defective
Signature Exit Path HP Sensor (S67) Error
SC798-23
B
The signature exit path HP sensor
did not go ON within the prescribed
time after the signature exit path
motor turned on to retract the
signature exit roller.
-or-
The signature exit path HP sensor
did not go OFF within the
prescribed time after the signature
exit path motor turned on to move
the signature exit roller.
•
Signature Exit Path Motor (M30)
defective
•
Signature Exit Path HP Sensor
(S67) defective
•
Sensor or motor connector loose,
broken, defective
Signature Exit Path Press Sensor (S68) Error
SC798-24
B
The signature exit path press sensor did
not go ON within the prescribed time after
the signature exit path motor turned on to
feed the book into the nip of the signature
exit roller.
-or-
The signature exit path press sensor did
not go OFF within the prescribed time
after the signature exit path motor turned
on to retract the signature exit roller.
•
Signature Exit Path Motor
(M30) defective
•
Signature Exit Path Press
Sensor (S68) defective
•
Sensor or motor connector
loose, broken, defective