SERVICE CALL CONDITIONS
SM
4-65
B234/B235/B236/D101/D102/D103
T
ro
u
b
le
-
s
h
o
o
ti
n
g
Book Registration Sensor (S88) Error
SC795-50
A
The value for the
adjustment of the
book registration
sensor was out of
range.
•
Slide motor (M44) connections loose, broken,
defective
•
Motor defective
•
Book registration sensor (S88) harness loose,
broken, defective
•
Sensor defective
LE Detection Sensor (S65) Error
SC795-51
A
No book could be detected in the
path for trimming (the sensor
could not detect a leading edge of
a book).
•
The book has slipped out of the grip
of the book rotation plates
Book Exit Sensor (S64) Error
SC795-52
A
No book could be detected at the
entrance of the trimming unit.
-or-
The book did not arrive in the
trimming unit because it jammed.
(The trim unit entrance sensor
(S92) did not go ON.)
•
Main grip lift motor (M22)
connections loose, broken, defective
•
Motor defective
•
Book exit sensor (S64) harness
loose, broken, defective
•
Sensor defective
Book Registration Sensor (S88) Error
SC795-53
A
A book was not
detected at the book
registration sensor
pair (the book
registration did not go
ON.
•
Book jammed, failed to arrive at book
registration sensor
•
Slide motor (M44) connections loose, broken,
defective
•
Motor defective
•
Book registration sensor (S88) harness loose,
broken, defective
•
Sensor defective
•
Sensor flag error, overload
Book Exit Sensor (S64) Error
SC795-54
A
The book exit sensor went ON
when the system was turned ON,
indicating that a book was at the
book exit sensor above the book
grip and rotation unit.
•
Book jammed at the entrance of the
book grip and rotation unit.
•
Book exit sensor (S64) defective
Exit Exit Sensor (S64) Error
SC795-55
A
The slave control board could
detect no paper at the entrance of
the trimming unit. The entrance
sensor did not detect the signature
within 6860 ms from when the
signature exited the gluing unit.
•
Trim unit entrance sensor (S92)
defective