SERVICE CALL CONDITIONS
SM
4-69
B234/B235/B236/D101/D102/D103
T
ro
u
b
le
-
s
h
o
o
ti
n
g
Spine Fold Close Sensor: Right (S69) Error
The right fold plate close sensor did not go ON within the prescribed time
after the spine fold plate motor: right turned on to close the fold plate, or the
close sensor on the right was already OFF when the spine fold plate was
supposed to close the plate.
-or-
The right spine fold plate close sensor did not go OFF within the prescribed
time after the spine fold plate motor: right turned on to open the plate, or the
spine fold page close sensor on the right was already ON when the spine fold
plate was supposed to move from the open to the closed position.
SC796-8
A
•
Spine fold motor: right (M29) defective
•
Spine fold close sensor: right (S69) defective
•
Sensor connector loose, broken, defective
Dual Spine Plate Sensor Error: Right
SC796-9
A
The spine fold HP sensor: right
(S66) and spine fold close
sensor: right (S69) turned ON
at the same time.
•
Spine fold HP sensor: right (S66)
defective
•
Spine fold close sensor: right (S69)
defective
•
Sensor connector loose, broken,
defective
Spine Plate Open Sensor (S62) Error
SC796-10
A
The spine plate open sensor did not go
ON within the prescribed time after the
spine plate motor turned on to open the
plate.
-or-
The spine plate open sensor did not go
OFF within the prescribed time after the
spine plate motor turned on to close the
plate.
•
Spine plate motor (M26)
defective
•
Spine plate open sensor
(S62) defective
•
Sensor or motor connector
loose, broken, defective
Spine Plate Closed Sensor (S63)
SC796-11
A
The spine plate close sensor did not go
ON within the prescribed time after the
spine plate motor turned on to close the
plate.
-or-
The spine plate close sensor did not go
OFF within the prescribed time after the
spine plate motor turned on to open the
plate.
•
Spine plate motor (M26)
defective
•
Spine plate closed sensor
(S63) defective
•
Motor or sensor connector
loose, broken, defective
Front Door Lock Error
SC796-12
A
The right front door sensor did
not go OFF even though the
front doors closed and locked.
-or-
The right front door sensor did
not go ON even though the
front doors released and
opened.
•
The right front door solenoid (SOL3)
defective
•
Right front door sensor (S30) defective
•
One or more of the front door switches
(MSW1, 2, 4, 5, 6, 7) is defective
•
Solenoid, sensor, or MSW connector
loose, broken, defective