SERVICE CALL CONDITIONS
SM
4-51
B234/B235/B236/D101/D102/D103
T
ro
u
b
le
-
s
h
o
o
ti
n
g
Spine alignment error
792-17
D
During pin alignment
operation, the pin did not
reach the up position or
return to the home position
with the prescribed time (400
ms), and one retry failed
within the same time limit.
•
Alignment pin motor (M602) connector loose,
broken, defective
•
Motor overload
•
Motor defective
•
Alignment pin HP sensor (S604) connector
loose, broken, defective, or sensor defective
•
Alignment pin up sensor (S610) connector
loose, broken, defective, or sensor defective
•
Stack not jogged correctly, or not punched
correctly
Binder unit not detected
792-18
D
The binder unit could not be
detected at initialization.
•
Drawer connector loose, broken,
defective
•
Drawer connector defective
Output belt unit rotation error
792-19
D
Detected at HP after the time
prescribed to leave the HP had
elapsed (more than 800 pulses) (1st
detection, jam, 2nd detection, SC
error)
-or-
Not detected at HP after the time
prescribed to arrive at the HP had
elapsed (more than 2300 pulses) (1st
detection, jam, 2nd detection, SC
error)
•
Output belt rotation motor (M403)
connector loose, broken, defective
•
Motor overload
•
Motor defective
•
Output belt rotation HP sensor
(S403) connector loose, broken,
defective
•
Sensor defective
Output belt 1 HP error
792-20
D
Detected at HP after the time
prescribed to leave the HP had elapsed
(more than 200 pulses) (1st detection,
jam, 2nd detection, SC error)
-or-
Not detected at HP after the time
prescribed to arrive at the HP had
elapsed (more than 2125 pulses) (1st
detection, jam, 2nd detection, SC error)
•
Output belt 1 motor (M401)
connector loose, broken, defective
•
Motor overload
•
Motor defective
•
Output belt 1 HP sensor (S401)
connector loose, broken, defective
•
Sensor defective