Memory Clear
The basic machine (the machine without the optional controller box) stores all the data in the NVRAM on
the BICU. The data is cleared by SP 5801 2 (see exceptions)
002
Main Motor Reverse
003
Quenching Lamp
The GDI machine (the machine with the optional controller box) stores the engine data in the NVRAM on
the BICU, and stores the other data in the NVRAM on the optional controller. To distinguish between the
engine data and the other data, see SP 5801 3 through 15. This service program (SP 5801) handles the
controller data. Any data that is not handled by SP 5801 is the engine data. The data in the BICU NVRAM
(engine data) is cleared by SP 5998 1 while the data in the controller NVRAM (controller data) is cleared
by SP 5801-xxx (see exceptions)
002
Main Motor Reverse
003
Quenching Lamp
Machine
Data
NVRAM
Cleared by
Remarks
Basic
All data
BICU
SP 5801 2
GDI
Engine data
BICU
SP 5998 1
Any data other than
controller data
Controller data
Controller
SP 5801-xxx
SCS, IMH, MCS,
Copier application,
Printer application,
Scanner application,
Web service/network
application, NCS, R-
Fax, DCS, UCS
- Exceptions -
SP 5801 2 (basic machine) and SP 5998 1 (GDI machine) clears most of the settings and counters stored
in the NVRAM on the BICU (the values return to their default values). However, the following settings are
not cleared:
• SP 5807 (Area Selection)
• SP 5811 1 (Serial Num Input [Code Set])
• SP 5811 3 (Serial Num Input [ID2 Code Display])
Using SP Modes
153
5
Summary of Contents for Aficio MP 1600L2
Page 1: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Field Service Manual 3 December 2010 ...
Page 2: ......
Page 12: ...10 ...
Page 14: ...Machine Configuration 1 Product Information 12 1 ...
Page 20: ...1 Product Information 18 1 ...
Page 70: ...2 Installation 68 2 ...
Page 71: ...3 Preventive Maintenance PM Tables See Appendices for the PM Tables 69 3 ...
Page 74: ...7 Wait until the message Completed shows 8 Quit the SP mode 3 Preventive Maintenance 72 3 ...
Page 139: ...PSU Power Supply Unit 1 Left cover p 79 2 PSU A All connectors x 6 Other Replacements 137 4 ...
Page 151: ...SP Mode Tables See Appendices for the SP Mode Tables SP Mode Tables 149 5 ...
Page 171: ...1 1 0 0 A5 SEF 1 1 1 0 B5 SEF 1 Detected Using SP Modes 169 5 ...
Page 207: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Appendices 3 December 2010 ...
Page 208: ......
Page 210: ...2 ...
Page 228: ...2 Appendix Preventive Maintenance 20 2 ...
Page 262: ...MEMO 54 ...
Page 263: ...MEMO 55 ...
Page 264: ...MEMO 56 EN ...