No.
Definition
Symptom
Possible Cause
551
A
Fusing thermistor open (rear)
The fusing temperature detected by
the thermistor is below 71
°
C and is
not corrected after the main power
switch is turned on.
• Fusing thermistor defective or out of position
• Power supply board defective
• Loose connectors
552
A
Fusing temperature warm-up error (rear)
The fusing temperature rises less
than 7 degrees in 2 seconds, and
this continues 5 times
consecutively.
The fusing temperature is not
detected in 25 or 35 seconds.
• Fusing thermistor defective or out of position
• Fusing lamp open
• Power supply board defective
553
A
Fusing overheat error (rear)
The fusing temperature is over
230
°
C for 1 second (detected by
the thermistor).
• Fusing thermistor defective
• Power supply board defective
555
A
Fusing lamp overheat error (rear)
After the fusing temperature
reaches the target temperature, the
fusing lamp does not turn off for 20
consecutive seconds.
• Fusing thermistor defective or out of position
• Power supply board defective
556
A
Unstable fusing temperature (rear)
The fusing temperature varies 50
°
C or more within 1 second, and this
occurs 2 consecutive times.
• Thermistor defective or out of position
• Power supply unit defective
559
Jam error detected 3 times in succession
• The exit sensor and the duplex
sensor detect a paper jam 3
times in succession
• This condition can occur
when SP 1159 1 is set to ‘on’.
The default is ‘off’.
Paper jams can occur for the following reasons.
• Dampness
• Paper curl
• Incorrect paper setting in the paper tray
• Stripper pawls coming apart
6. Troubleshooting
184
6
Summary of Contents for Aficio MP 1600L2
Page 1: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Field Service Manual 3 December 2010 ...
Page 2: ......
Page 12: ...10 ...
Page 14: ...Machine Configuration 1 Product Information 12 1 ...
Page 20: ...1 Product Information 18 1 ...
Page 70: ...2 Installation 68 2 ...
Page 71: ...3 Preventive Maintenance PM Tables See Appendices for the PM Tables 69 3 ...
Page 74: ...7 Wait until the message Completed shows 8 Quit the SP mode 3 Preventive Maintenance 72 3 ...
Page 139: ...PSU Power Supply Unit 1 Left cover p 79 2 PSU A All connectors x 6 Other Replacements 137 4 ...
Page 151: ...SP Mode Tables See Appendices for the SP Mode Tables SP Mode Tables 149 5 ...
Page 171: ...1 1 0 0 A5 SEF 1 1 1 0 B5 SEF 1 Detected Using SP Modes 169 5 ...
Page 207: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Appendices 3 December 2010 ...
Page 208: ......
Page 210: ...2 ...
Page 228: ...2 Appendix Preventive Maintenance 20 2 ...
Page 262: ...MEMO 54 ...
Page 263: ...MEMO 55 ...
Page 264: ...MEMO 56 EN ...