2928
Toner End Clear
2928 1
Clears the toner end condition without adding new toner. The following are cleared:
Toner end indicator (goes out)
Toner near-end counter
Toner near-end level
This function should generally not be used. If you clear the toner end condition without
adding new toner, there is a risk that the drum may eventually begin to attract carrier after
many more copies are made and toner runs out. This attracted carrier may damage the
drum.
2929*
Vref Limits
Adjust the upper or lower Vref limit.
2929 1 Upper
[0.50 to 3.50 / 3.20 / 0.01V/step] DFU
2929 2 Lower
[0.50 to 3.50 / 0.70 / 0.01V/step] DFU
2994*
ID Sensor Detection Temperature
[30 to 90 / 30 / 1
°
C/step]
2994 1
While the machine is recovering from an energy saver mode, or while the machine starts,
the controller ignores the ID-sensor signals if the fusing temperature is at the specified value
or higher.
2996*
Transfer Roller Cleaning
2996 1
Selects whether the transfer roller is cleaned before each copy job. Set this to "1" if dirty
background is appearing on the reverse side of the first page of copy jobs. Note that this
will increase the time required to generate the first copy. If the setting is "0", the transfer
roller is never cleaned ( Transfer Roller Cleaning).
2997*
Toner Density Sensor Standard
Voltage
[0 / 2.5 / 5/ 0.01V/step] DFU
2998*
Main Scan Magnification
[–0.5 to +0.5 / 0.0 / 0.1%/step]
2998 1
Adjusts the magnification along the main scan direction, for all print modes (copy, printing).
The specification is 100 ± 1.0% ( Copy Adjustments Printing/Scanning).
3. Appendix: SP Mode Tables
30
3
Summary of Contents for Aficio MP 1600L2
Page 1: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Field Service Manual 3 December 2010 ...
Page 2: ......
Page 12: ...10 ...
Page 14: ...Machine Configuration 1 Product Information 12 1 ...
Page 20: ...1 Product Information 18 1 ...
Page 70: ...2 Installation 68 2 ...
Page 71: ...3 Preventive Maintenance PM Tables See Appendices for the PM Tables 69 3 ...
Page 74: ...7 Wait until the message Completed shows 8 Quit the SP mode 3 Preventive Maintenance 72 3 ...
Page 139: ...PSU Power Supply Unit 1 Left cover p 79 2 PSU A All connectors x 6 Other Replacements 137 4 ...
Page 151: ...SP Mode Tables See Appendices for the SP Mode Tables SP Mode Tables 149 5 ...
Page 171: ...1 1 0 0 A5 SEF 1 1 1 0 B5 SEF 1 Detected Using SP Modes 169 5 ...
Page 207: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Appendices 3 December 2010 ...
Page 208: ......
Page 210: ...2 ...
Page 228: ...2 Appendix Preventive Maintenance 20 2 ...
Page 262: ...MEMO 54 ...
Page 263: ...MEMO 55 ...
Page 264: ...MEMO 56 EN ...