No.
Definition
Symptom
Possible Cause
955
B
Image transfer error
The controller is not able to transfer
images when the engine needs
them.
• Application program defective
964
B
Status error (laser optics housing unit)
The optics-housing unit does not
become ready within 17 seconds
after the request.
• Software defective
981
B
NVRAM error
The machine detects a discrepancy
in the NVRAM write/read data
when attempting to save actual
data to the NVRAM (i.e. during
actual use).
• NVRAM defective
• Poor connection between BICU and
NVRAM
• NVRAM is not connected
• BICU defective
982
B
Localization error
The localization settings in the
nonvolatile ROM and RAM are
different (SP5807).
• First machine start after the NVRAM is
replaced
• Incorrect localization setting
• NVRAM defective
984
B
Print image transfer error
Print images are not transferred.
• Controller defective
• BICU board defective
• Poor connection between controller and
BICU
6. Troubleshooting
190
6
Summary of Contents for Aficio MP 1600L2
Page 1: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Field Service Manual 3 December 2010 ...
Page 2: ......
Page 12: ...10 ...
Page 14: ...Machine Configuration 1 Product Information 12 1 ...
Page 20: ...1 Product Information 18 1 ...
Page 70: ...2 Installation 68 2 ...
Page 71: ...3 Preventive Maintenance PM Tables See Appendices for the PM Tables 69 3 ...
Page 74: ...7 Wait until the message Completed shows 8 Quit the SP mode 3 Preventive Maintenance 72 3 ...
Page 139: ...PSU Power Supply Unit 1 Left cover p 79 2 PSU A All connectors x 6 Other Replacements 137 4 ...
Page 151: ...SP Mode Tables See Appendices for the SP Mode Tables SP Mode Tables 149 5 ...
Page 171: ...1 1 0 0 A5 SEF 1 1 1 0 B5 SEF 1 Detected Using SP Modes 169 5 ...
Page 207: ...Model K C3 5L Machine Code B244 B276 B277 B268 B269 Appendices 3 December 2010 ...
Page 208: ......
Page 210: ...2 ...
Page 228: ...2 Appendix Preventive Maintenance 20 2 ...
Page 262: ...MEMO 54 ...
Page 263: ...MEMO 55 ...
Page 264: ...MEMO 56 EN ...