12
Revision 2
Step 4
– Removing Motor Cover for Mounting:
•
Unscrew the two motor cover screws located at each side of the motor cover.
•
Remove the rubber grommet below the spring limit switch (as per fig 5).
Please Note: the rubber grommet must be fitted back onto the motor cover once the
cover has been re-fitted/replaced onto the base of the motor.
Step 5 - Drilling Holes for Anchor Bolts:
•
Ensure the mounting plate is positioned within the marked corners.
•
Proceed to mark the (4) positions for your anchor bolts ready for drilling (refer to
Fig 6).
•
Remove Mounting plate.
•
Using a M12 masonry drill bit, drill holes to a minimum depth of 120mm (Fig 7).
Fig 5
Mark
corners
of the
mounting
plate with
a pencil,
chalk, or
similar.
Sliding Gate Frame (in open position)
Fig 4