19
Revision 2
Step 10
– Testing the Limit Travel Stops:
Testing the closed position
•
Ensure motor is plugged in as per step 9 and the gate is
in the open position.
•
Press remote (remotes included in kit are factory
paired to the motor). The gate will begin to close.
•
The limit travel stops will hit the spring limit switch and the
gate will stop.
•
When the gate stops, measure the distance remaining
between the gate and the desired closed position.
•
You have now determined the closed position of the gate
when the travel limit stop hits the spring limit switch.
•
Adjust the limit travel stops from the measurement
you have taken to get your final gate closed position.
The ideal closed final position for the gate frame is 10-
15mm from closed gate end catch (GTR019).
Testing the open position
•
Press remote. The gate will begin to open.
•
The limit travel stop will hit the spring limit switch and the
gate will stop.
•
When the gate stops, measure the distance remaining
between the gate and the desired open position.
•
You have now determined the open position of the gate
when the travel limit stop hits the spring limit switch.
•
Adjust the limit travel stops from the measurement
you have taken to get your final gate open position.
The ideal open final position for the gate frame is
10-15mm from the gate stopper (GTR017).
To Reset:
When setting new limit stop positions please ensure that you turn the power off and
then on again. Turning the power off will reset the limit stop memory, allowing for new
limit travel stop positions to be recognised by the motor.
Fig 23
Warning:
Please allow space to
ensure the gate does not
impact against the gate
catch or the end stop.
See fig 23