background image

Product:

TVPRP868N09

Doc:

T611.02

Date:

23/03/2016

Control system for garage doors

Installer’s instruction manual

Summary of Contents for TVPRP868N09

Page 1: ...Product TVPRP868N09 Doc T611 02 Date 23 03 2016 Control system for garage doors Installer s instruction manual...

Page 2: ...p 10 4 Transmitters memorization p 11 12 4 1 Single channel 4 2 Double channel 4 3 Single channel Courtesy light ON OFF 4 4 Alarm function shock sensor memorization 4 5 Remote memorization of a trans...

Page 3: ...rs Wireless safety edge both resistive 8K2 and Infrared with auto test TCSP240A09B Alarm function in combination with shock sensor TVSSH868A01 and external speaker CONNECTIONS FUNCTIONING Wired input...

Page 4: ...ac 3 Hand transmitter 4 Safety edge wireless transmitter 1 4 2 3 6 9 8 1 4 2 3 1 PRP control unit 2 Tubular motor 230Vac 3 Hand transmitter 4 Safety edge wireless transmitter 5 External flashing light...

Page 5: ...5 2 1 MOUNTING THE PRODUCT BOX DIMENSIONS OPENING THE COVER 85 mm 145 mm 290 mm 80 mm 95 mm 120 mm MOUNTING SIDE...

Page 6: ...infrared low consumption barrier In case of any obstacle is detected during the closing the SLAVE sends an alarm to the MASTER that immediately stop the manoeuvre and reverse the movement The system e...

Page 7: ...nfra red safety edge input brown 17 Infra red safety edge input green 18 Infra red safety edge input white 19 Push button common COM 20 Push button step by step N O 21 Emergency STOP push button N C 2...

Page 8: ...V N O COM N C 0V 12V 24V 12 13 14 15 16 17 18 19 20 21 22 RX FTC010 TX FTC010 REFLEX COM N C 8K2 12Vdc 15Vdc 8K2 12 13 14 15 16 17 18 19 20 21 22 12 13 14 15 16 17 18 19 20 21 22 12 13 14 15 16 17 18...

Page 9: ...n of the radio card MASTER 4 In case of correct memorization L2 will flash led button Check the system pressing the button of the bottom slat transmitter SLAVE and keeping it pressed Slave led solid O...

Page 10: ...andards in order to avoid any accidental activation of the safety edge This procedure must be performed by qualified installer only who will take charge of its correct application WARNING this procedu...

Page 11: ...n of two buttons of any transmitter in one step with function OPEN STOP CLOSE STOP OPEN STOP CLOSE Press P1 twice and keep it pressed The buzzer emits a continuous sound Press any button of the pair t...

Page 12: ...d memorized new 4 4 Alarm function shock sensor memorization The wireless shock sensor optional detects any attempt of breaking or entering and send a signal to the control unit that will activate the...

Page 13: ...ep it pressed for at least 10 seconds The buzzer emits an intermittent sound Release the button once the sound becomes continuous P1 continuous sound 10 s keep it pressed intermittent sound P1 P1 P1 P...

Page 14: ...e setting This procedure configures the time of activation of the courtesy light The default time is 60 seconds It is possible to set the time from 60 seconds to 12 hours Note The procedure can be exe...

Page 15: ...he wired inputs are still enabled ACTIVATION Press the STOP button in the front cover and keep it pressed for 5 seconds The buzzer makes one beep DEACTIVATION Press STOP button in the front cover and...

Page 16: ...installation of the control unit has to be done by fixing the box vertically with the cable glands downwards The product is in conformity with the RAEE and RoHS directive The earth wire must be longer...

Page 17: ...ster must be paired with the bottom slat transmitter slave Bottom slat transmitter TCSP checks Check type lithium 3 6V polarity and charge level of the batteries Check functionality by pressing the bu...

Page 18: ...noeuvre until the top limit has reached In the closure the door hits the floor and opens again The bottom limit could be too low adjust it upwards In case of uneven floors it could be necessary deacti...

Page 19: ...ransmitter with the screw 2 channel hand transmitter Carrier frequency 868 3 MHz Power supply 3V 10 lithium battery CR2032 Consumption when transmitting 12 mA Operating temperature range 10 55 C Warni...

Page 20: ...ation France France info telecofrance com Teleco Automation GmbH Germany info de telecoautomation com Teleco Automation Oceania Pty Ltd Australia info telecoautomation com au Headquarters Teleco Autom...

Reviews: