Beijing RichAuto S&T Co., Ltd.
Forging ahead and determined to win 19
and reduce the operating speed of the entire graph. System default:linear acceleration is 800 mm/s
2
,
curve acceleration is 1000 mm/s
2
, the proposed curve acceleration is 1-1.5 times the linear
acceleration value.
6.
Start Speed Unit
:
mm/minute
The speed of axis started directly from standstill. Not starting from zero speed, but starting
directly from a certain speed,so it can shorten the overall processing time,but do not set this speed
too high. Set too high, it will cause the motor losing steps, jitter and even whistle;Set too small, it
will reduce the operating speed of the entire graph. If the inertia of motion axes (axis heavier),
users can set a smaller start speed, if the inertia of motion axes smaller (lighter shaft), users can set
it bigger.
7.
Voltage Setup
Set input and output signal terminal status
,
―
↓
‖ means normal open
,
―
↑
‖ means normal
closed.Including two rows of arrow
:
The upper arrow indicates the input level
:
Set input signal level.The top four: 0 ,1 ,2 ,3
positions correspond X ,Y ,Z axis back home ,toolsetting signal
;
4-7: driver alarm ,hard
limit ,E-stop signal,pedal switch.
The under arrow indicates the output level
:
Set output signal level. The top four: 0
、
1
、
2
、
3
positions correspond spindleOn/Off
、
multi-speed 1
、
multi-speed 2
、
multi-speed 3 signal
,
5
、
6:4
、
5 positions correspond alarm indicator
、
work indicator signal.
Setting
:
Press
“
”
/
“
”
to move around
,
Press
“
”
、
“
‖to
move up and down
,
press
“
”
to change the direction of the arrow.
8.
C.A.D.(Tool sensor) Thickness Unit
:
mm
This thickness should input by actual
,
if it is bigger than the actual thickness ,Z axis may cut