SpaceLogger
®
.S10
User Manual
©2012-13 Richard Paul Russell Limited, New Harbour Building, Bath Road, Lymington SO41 3SE United Kingdom
Tel +44 (0) 1590 679755 Fax +44 (0) 1590 688577 e-mail [email protected] web www.r-p-r.co.uk
- 26 -
017SL167/3 04/09/13
7
SPACELOGGER.S10 SPECIFICATION
Physical
Dimensions
Width: 67 mm
Depth: 67 mm
Height: 28 mm (excluding optional rubber feet)
Weight 75g
Enclosure material GP ABS (UL94-HB) plastic and acrylic
Connections
Type
Screwless terminals capable of accepting wire 0.32 to 0.64 mm
diameter, (AWG 28 to 22 conductors)
RS232 Input 1
Transmission standard
RS232 and TTL/CMOS* logic compatible.
*V
IL
Input threshold low: 0.6V min 1.2V Typ.
V
IH
Input threshold high: 1.5V Typ, 2.4V max
8 bits and no parity
Logic inversion on received data is selectable.
Transmission speed
9600 Baud (default) or selectable from 115200, 57600, 38400,
19200, 4800, 2400, 1200, 300 or 110 Baud
Data Sample
Records only the data between specified start (STX/STX2) and
end (ETX/ETX2) identifiers (unless configured to LOG_ALL=Y)
RS232 Input 2
Transmission standard
RS232 compatible, 8 bits and no parity
Transmission speed
4800 Baud only
Data Sample
Records only the data between specified start (STX2) and end
(ETX2) identifiers (unless configured to LOG_ALL=Y)
Switch Inputs
Max input voltage
Must not exceed 3V
Current out
7µA max
RS232 Output 1
Transmission standard
RS232 compatible, 8 bits and no parity
Transmission speed
9600 Baud (default) or selectable from 115200, 57600, 38400,
19200, 4800, 2400, 1200, 300 or 110 Baud
Data Transmission
Output of data defined by command OUTPUT. Output of
handshake response unless already allocated to output data.
Output of file STARTUP.TXT.
RS232 Output 2
Transmission standard
RS232 compatible, 8 bits and no parity
Transmission speed
4800 Baud only
Data Transmission
Only used for handshake response if RS232 Output 1 is already
allocated to output data.
Data Storage
Data Storage Card Removable SD, MMC or MMC mobile card
Data Capacity 2 Gbyte (max)
File System
FAT16 or FAT32 with 8.3 file names
Sector size 512 Bytes
Data logging interval
Default is to log every data sample output by the device/sensor
or select logging interval from 1 to 60 seconds. Data sampling
may be disabled so all data is recorded.
Audible / Visual
Indicators
LED Indicators
Green: Ready to record data
Red: Power on | Writing data to SD card | Waiting for second
data sample in timeout mode
Audio Bleeper
Two tone signal on correct card insertion.
Single tone when data purge button depressed.
Four bleeps per minute when time & date not set.
Real Time Clock
Accuracy ±40 ppm at 25 ºC
Backup battery CR2032
Power
Power requirement 7 to 30 Vdc
Current at 12Vdc 10 mA typical
Supply input protection Polarity reversal protected and internal re-settable fuse
– 140 mA
Connection 1.3 mm centre pin DC connector, or