background image

R3-081016 

  

DATA LOGGER 

Model DL-SA11 

User’s Manual 

For Sales Information Please Contact 

RoadTrucker Inc 

(www.RoadTrucker.com) 

8312 Sidbury Rd. 

Wilmington, NC 28411 

(800) 507-0482 / (910) 686-4281

Summary of Contents for DL-SA11

Page 1: ...R3 081016 1 DATA LOGGER Model DL SA11 User s Manual For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686 4281 ...

Page 2: ...ort type Excel and AI PDF Power supply single use lithium battery 3 6V replaceable Battery life at least 12 months at 25 C with 15 min record interval In the package DL SA11 temperature data logger User s manual Using the data logger Download the data management software from the link below http accucoldloggers com dlsa11 Data management software can be downloaded from the software platform by cli...

Page 3: ...he set time View data instantly If you need to view simple statistical information you may directly press the button to turn the page and check The LCD screen can display MKT average value Max value and Min value Mean Kinetic Temperature MKT is a simplified way of expressing the overall effect of temperature fluctuations during storage or shipment of perishable goods If you need detailed informati...

Page 4: ...ia software View data Connect the data logger to the computer via USB and then view the data View report via the data management software Open the software and import the data as Excel Adobe Illustrator Artwork AI or PDF report The software will display the configuration information and recorded data Display menu instructions Different screens are displayed when the unit is running Below are vario...

Page 5: ...e Menu 8 Min temperature value Fig 9 Fig 10 Menu 9 10 11 Set upper limit of temperature See Fig 11 12 13 Fig 11 Upper limit 3 Fig 12 Upper limit 2 Fig 13 Upper limit 1 Menu 12 13 Set lower limit of temperature See Fig 14 15 Fig 14 Lower limit 1 Fig 15 Lower limit 2 Other status Fig 16 Deleting data Fig 17 Recovering data Power on Fig 18 Generating report Fig 19 USB connection For Sales Information...

Page 6: ...y will be marked as alarm status on top right corner of the first page otherwise it is in normal status Finish viewing Exit the data logger after viewing the report Product diagram Replacing the battery PLEASE NOTE Before replacing the battery you must first shut down the data logger If not when restarting the logger the time will be incorrect Step 1 Rotate the transparent cap and remove it in the...

Page 7: ...all the new one See Fig 23 Fig 23 Step 5 Adjust the button and the internal light pipe to the same side snap the compartment shut See Fig 24 Fig 24 Step 6 To re install the transparent cap rotate it in the direction shown in Fig 25 Fig 25 For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686 4281 ...

Page 8: ...gger Database query interface displays all saved data information Manually save data if current data is not saved into database then press this button to save data For first time recording data the system will automatically save the data and display the prompt of auto data saving If new data is recorded and logger is inserted into computer once more user needs to save the data manually by clicking...

Page 9: ...cumulated alarm time Highest Max Temperature Violations Times alarm occurs Lowest Min Temperature Status Logger alarm status Average Average Temperature RH Relative Humidity Stop Mode Stop mode Set Status Logger alarm status Stop mode actual Actual stop mode T Temperature Start Time Start time RH Relative Humidity Multiple Work Permits logger to be started or stopped several times Data Graph Funct...

Page 10: ...ge data Displays previous page data Displays next page data Displays last page data Skips to a specific page For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686 4281 ...

Page 11: ...cted logger Displays all loggers that have exceeded upper lower limit Displays all recording including normal temperature data and over temperature data Data management function Back to home page For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686 4281 ...

Page 12: ...ta in the format of ELT Data restore restores ELT file and reads it by software Back to home page 5 Parameter setting page For Sales Information Please Contact RoadTrucker Inc www RoadTrucker com 8312 Sidbury Rd Wilmington NC 28411 800 507 0482 910 686 4281 ...

Page 13: ...sword Setting password Stop Mode Logger stop modes Multiple Alarm Set several alarm thresholds Multiple Work Permit logger to be started or stopped several times Probe Type Temperature sensor type internal or external Start time Logger starts automatically at set time Saves parameters Saves parameter setting Loads parameter setting Back to home page Sensor adjustment 6 Sensor Adjustment For Sales ...

Page 14: ...manship Service must be provided by a designated service company Outside the 48 states all parts are warranted for 90 days from manufacturing defects Plastic parts are warranted to be manufactured to commercially acceptable standards and are not covered from damage during handling or breakage Warrantor will not pay for damage resulting from accident alteration misuse abuse fire flood acts of God i...

Reviews: