background image

Page 

12

 / 

30

 

 

EN -

 Original instructions

 

I. Parts List 
II. Characteristics 

III. Safety instructions 
IV. Getting Started 

V. Operation 
VI. Maintenance and Storage 

 

I. PARTS LIST 

See Fig.1 

 

II. CHARACTERISTICS  

See table 1 

 
III. SAFETY INSTRUCTIONS 
 

Before using this product, read and understand all safety instructions. 
Always follow the safety instructions to minimize risk of damage to property, and to minimize any 
risk of damages and injuries to persons and animals. 

 
Symbols 

 

 

Caution! Risk of injury and/or damage and/or deterioration of product in case of non-compliance to 
safety requirements 

 

Read the instructions manual.  
 

 

Keep persons (esp. children) and animals away from product and working area 

 

Disconnect product from its power source before maintenance, cleaning or any intervention on 
product; or when you do not use product. 
Disconnect product from its main power source, if product, power cable, or extension cord is 
damaged or cut during operation. 
Unplug product by pulling the plug. Do not pull the cable. 

 

Do not dispose of this product with household rubbish. 
Dispose of this product in the nearest recycle centre. 
Please contact your local authority or local recycle centre for further information for its safe 
disposal. 

 

3.1- READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT. 

1. Keep work area clean

 

Cluttered areas and benches invite accidents and injuries.

 

2. Consider work area environment

 

Keep work area well lit (natural light or sufficient artificial lighting). 
Keep work area well ventilated. 
Do not use product where there is risk to cause fire or explosion (in the presence of flammable liquids, 
solids or gas).

 

3. Guard against electric shock

 

Avoid body contact with earthed or grounded surfaces (e.g. pipes, radiators, ranges, refrigerators).

 

4. Keep children away

 

Do not let bystanders touch the product or its power cable or extension cord.  
All bystanders (esp. children) should be kept away from product and work area. 
Keep the product away from children or from their environment. Never allow children to operate the 
appliance. Children should be supervised to ensure that they do not play with the appliance. 
5. Store idle products 
When not in use, product should be stored in a dry, high or locked up place, out of reach of children. 
6. Do not force the product 
It will do the job better and safer at the rate speed for which it is intended. 
Do not use the product for purposes other than those for which it is intended. The product will do a 
better and safer job if it is used only for the purposes it was designed for. 
7. Use the right product 
Do not force small products or attachments to do the job of a heavy-duty product.  

Summary of Contents for Ribiland 100QJD210-0.75

Page 1: ...al IT POMPA DI GRANDE PROFONDIT Manuale di istruzioni e di manutenzione R f Art Nr PRPGP750 67 511911 R f Art Nr PRPGP750 60 1TL 516506 R f Art Nr PRPGP750 95 40 512006 R f Art Nr PRPGP750 150 516516...

Page 2: ...amento non corretto pu causare lesioni e o danni Conservare il presente manuale per futuri consulti Attention Ces pompes ne sont pas destin es aux piscines Dans aucun cas elles ne doivent tre utilis e...

Page 3: ...ales ou votre d chetterie locale 3 1 LIRE TOUTES LES INSTRUCTIONS AVANT D UTILISER CE PRODUIT 1 Garder l aire de travail propre Des aires de travail et des tablis encombr s sont source d accidents et...

Page 4: ...r changer les accessoires 14 Eviter les d marrages intempestifs S assurer que l interrupteur est en position arr t avant de brancher la source d alimentation 15 Utilisation de rallonge Lorsque le prod...

Page 5: ...limentation doit tre contr l p riodiquement et avant chaque emploi pour v rifier qu il ne pr sente pas des signes de vieillissement ou de dommages 4 Si une rallonge est utilis e s assurer qu elle est...

Page 6: ...ertaine profondeur c S assurer qu il n y a pas de rejets toxiques ou des gaz nocifs pr sents dans l atmosph re d Si l installation demande de la soudure veillez prendre toutes les pr cautions n cessai...

Page 7: ...mmand e 5 Installez des sondes de niveau d eau qui coupent l alimentation de la pompe avant que le niveau d eau ne descende un niveau tel que la pompe soit expos e 4 3 Branchement lectrique 4 3 1 Alim...

Page 8: ...Si la pompe est install e dans un lieu clos avec manation de vapeurs nocives ex puisard l installation doit tre r alis e conform ment la l gislation locale et ou nationale en vigueur par du personnel...

Page 9: ...ter imm diatement le moteur et rechercher les raisons Contr ler r guli rement le niveau d eau pendant fonctionnement de la pompe de mani re ne pas tomber sous le niveau recommand car la pompe ne peut...

Page 10: ...mpe 4 Ne pas utiliser de produit d entretien agressif solvants d tergents ni d ponge abrasive ni d objets tranchants ou pointus 5 L o il y a le risque de gel ou lorsque la pompe n est pas suffisamment...

Page 11: ...un sp cialiste 2 Lib rer et nettoyer la turbine 3 faites remplacer le stator par un service agr Bobinage du stator grill 1 La pompe a fonctionn trop longtemps avec une phase perdue 2 Court circuit au...

Page 12: ...posal 3 1 READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT 1 Keep work area clean Cluttered areas and benches invite accidents and injuries 2 Consider work area environment Keep work area well li...

Page 13: ...lert Watch what you are doing Use common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reu...

Page 14: ...d European standards The wire section in the cable should be equal to or greater than 1mm2 The cable should not be lighter than cables of H07 RN F 6 When disconnecting the power cable from the socket...

Page 15: ...ameplate of the pump whether in accordance with the demands of application conditions 4 Check that the shaft of the pump can rotate freely 4 1 2 Check the motor 1 Firstly check on the name plate that...

Page 16: ...or at the end of power cable and finally make earth grounding connection with the ground wire The wire identified by the colour combination green yellow shall be grounded safely to prevent electric sh...

Page 17: ...rting the pump check the direction of motor rotation trial run the pump for no more than 1 minute to check the motor rotates counter clockwise when looking at pump from above that electrical connectio...

Page 18: ...pump is still connected to the power supply 2 The pump control box is protected by a thermal safety In the event of overheating the motor stops automatically As soon as the temperature returns to norm...

Page 19: ...ch disconnected or fuse burnt 2 Impeller clogged 3 Stator winding burnt 1 check whether the head in use or power voltage are in compliance with requirements and adjust accordingly 2 Remove foreign mat...

Page 20: ...posto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 1 LEGGERE TUTTE LE INFORMAZIONI PRIMA DI UTILIZZARE IL PRODOTTO 1 Mantenere in ordine l area di lavoro Il dis...

Page 21: ...ndo l attrezzo utilizzato con un estensione utilizzare soltanto estensioni concepite e previste per sopportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa P...

Page 22: ...te una prolunga verificate che sia omologata Tenetela lontana da spigoli taglienti fonti di calore e combustibili 5 La presa mobile della prolunga deve essere di tipo 2 poli terra da 10 16A 250V secon...

Page 23: ...trata e in uscita f Attenzione se avete dubbi sulla sicurezza della pompa non fatene uso 4 1 Disimballagio 4 1 1 Controllare la pompa 1 Rimuovere il prodotto dal suo imballaggio e controllare che l at...

Page 24: ...monofase 220 240 V sono questi i valori limite consentito 50 60Hz la fluttuazione di tensione sia entro 0 94 1 06 volte il valore nominale 3 Evitare il contatto tra l alimentazione e il liquido da po...

Page 25: ...un mattone 4 Ispezionare l albero della pompa il quale dovrebbe essere libero di ruotare 5 La pompa pu essere installata sia con tubi in metallo che possono essere utilizzati per sostenere la pompa c...

Page 26: ...ad uso domestico industriale o agricolo per aspirare acque chiare con particelle in sospensione inferiori a 0 2mm o 0 5mm ved Caratteristiche 2 La pompa totalmente sommergibile la profondit di immersi...

Page 27: ...mente i seguenti componento la condizione dei cavi e anelli soprattutto il loro collegamento 6 2 Ricerca guasti Non tentare mai di smontare la pompa In caso di necessita fare controllare la pompa da u...

Page 28: ...chiave o fuori dalla portata dei bambini 6 5 Smaltimento Non gettare la pompa con i rifiuti domestici non gettare nell ambiente Portare la pompa in un centro di rifiuti o di raccolta o chiedere consig...

Page 29: ...xample IT Fig 2 Esempio di installazione 1 Alimentation principale 2 Bo tier de contr le 3 Tuyau de refoulement 4 Vanne 5 Support pompe 6 Enceinte de protection de la pompe 7 Sonde sup rieure niveau d...

Page 30: ...turbines 19 turbines 14 turbines Capacit de refoulement maxi Max Delivery capacity Capacit di scarico 4800 l h 3000 l h 1800 l h 4900 l h 4800 l h 4800 l h Pression maxi Max pressure Pressione max 6 7...