background image

Page 

13

 / 

30

 

 

8. Dress properly 
When installing, do not wear loose clothing or jewellery; they can be caught in moving parts.  
Wear protecting hair covering to contain long hair. 
9. Use protective equipment 
When installing, wear protective equipment appropriate to working conditions and work environment 
Wear protective helmet, safety goggles, ear mufflers, face or dust mask, rubber gloves and non-skid 
footwear to reduce the risk of personal injury during products use or manipulation. 
10. Do not abuse the power cable 
Never carry the product by the cable or yank it to disconnect it from the socket.  
Keep the cable away from heat, oil and sharp edges. 
Inspect product cable periodically and if damaged have it repaired by an authorized service facility.  
Inspect extension cords periodically and replace, if damaged.  
11. Do not overreach 
When installing, keep proper footing and balance at all times. 
12. Maintain product with care 
Keep product clean for better and safer performance.  
13. Disconnect product 
When not in use, before servicing and when changing accessories. 
14. Avoid unintentional starting 
Ensure switch is off when plugging in. 
15. Use of extension leads  
When product is used with extension cord, ensure that extension cord withstands product ratings. 
If used outdoors, use only extension cords intended for outdoor use. 
16. Stay alert 
Watch what you are doing. Use common sense.  
Do not operate product when you are tired, under the influence of alcohol, prescription medicines or 
drugs. 
17. Check damaged parts 
Before further use or reuse of the product, it should be carefully checked to determine that it will 
operate properly and perform its intended function.  
18. Defective switches or other part that is damaged should be properly repaired or 
replaced by an authorized service centre. Do not use the product if the switch does not turn it on and 
off. 
19. Warning 
The use of any accessory or attachment, other than those recommended in this instruction manual, 
may present a risk of injury to persons or animals and may cause damages. 
The user and/or operator are responsible for any damages or injury caused to properties and/or 
persons. 
20. Have your product repaired by a qualified person 
Unless otherwise indicated in this instruction manual, repairs or replacement of any damaged part in 
an authorized service centre is recommended. 
This electric product is in accordance with the relevant safety requirements. Repairs should only be 
carried out by qualified persons using original spare parts, otherwise this may result in considerable 
danger to the user. 
21. Remarks: 
The safety precautions and instructions given in this manual are unable to cover in detail all the 
conditions and situations that may arise.  
The operator and/or user must use common sense and caution when operating the product especially 
for any matters that are not referred in the above 
 

Summary of Contents for Ribiland 100QJD210-0.75

Page 1: ...al IT POMPA DI GRANDE PROFONDIT Manuale di istruzioni e di manutenzione R f Art Nr PRPGP750 67 511911 R f Art Nr PRPGP750 60 1TL 516506 R f Art Nr PRPGP750 95 40 512006 R f Art Nr PRPGP750 150 516516...

Page 2: ...amento non corretto pu causare lesioni e o danni Conservare il presente manuale per futuri consulti Attention Ces pompes ne sont pas destin es aux piscines Dans aucun cas elles ne doivent tre utilis e...

Page 3: ...ales ou votre d chetterie locale 3 1 LIRE TOUTES LES INSTRUCTIONS AVANT D UTILISER CE PRODUIT 1 Garder l aire de travail propre Des aires de travail et des tablis encombr s sont source d accidents et...

Page 4: ...r changer les accessoires 14 Eviter les d marrages intempestifs S assurer que l interrupteur est en position arr t avant de brancher la source d alimentation 15 Utilisation de rallonge Lorsque le prod...

Page 5: ...limentation doit tre contr l p riodiquement et avant chaque emploi pour v rifier qu il ne pr sente pas des signes de vieillissement ou de dommages 4 Si une rallonge est utilis e s assurer qu elle est...

Page 6: ...ertaine profondeur c S assurer qu il n y a pas de rejets toxiques ou des gaz nocifs pr sents dans l atmosph re d Si l installation demande de la soudure veillez prendre toutes les pr cautions n cessai...

Page 7: ...mmand e 5 Installez des sondes de niveau d eau qui coupent l alimentation de la pompe avant que le niveau d eau ne descende un niveau tel que la pompe soit expos e 4 3 Branchement lectrique 4 3 1 Alim...

Page 8: ...Si la pompe est install e dans un lieu clos avec manation de vapeurs nocives ex puisard l installation doit tre r alis e conform ment la l gislation locale et ou nationale en vigueur par du personnel...

Page 9: ...ter imm diatement le moteur et rechercher les raisons Contr ler r guli rement le niveau d eau pendant fonctionnement de la pompe de mani re ne pas tomber sous le niveau recommand car la pompe ne peut...

Page 10: ...mpe 4 Ne pas utiliser de produit d entretien agressif solvants d tergents ni d ponge abrasive ni d objets tranchants ou pointus 5 L o il y a le risque de gel ou lorsque la pompe n est pas suffisamment...

Page 11: ...un sp cialiste 2 Lib rer et nettoyer la turbine 3 faites remplacer le stator par un service agr Bobinage du stator grill 1 La pompe a fonctionn trop longtemps avec une phase perdue 2 Court circuit au...

Page 12: ...posal 3 1 READ ALL THE INFORMATION BEFORE OPERATING THE PRODUCT 1 Keep work area clean Cluttered areas and benches invite accidents and injuries 2 Consider work area environment Keep work area well li...

Page 13: ...lert Watch what you are doing Use common sense Do not operate product when you are tired under the influence of alcohol prescription medicines or drugs 17 Check damaged parts Before further use or reu...

Page 14: ...d European standards The wire section in the cable should be equal to or greater than 1mm2 The cable should not be lighter than cables of H07 RN F 6 When disconnecting the power cable from the socket...

Page 15: ...ameplate of the pump whether in accordance with the demands of application conditions 4 Check that the shaft of the pump can rotate freely 4 1 2 Check the motor 1 Firstly check on the name plate that...

Page 16: ...or at the end of power cable and finally make earth grounding connection with the ground wire The wire identified by the colour combination green yellow shall be grounded safely to prevent electric sh...

Page 17: ...rting the pump check the direction of motor rotation trial run the pump for no more than 1 minute to check the motor rotates counter clockwise when looking at pump from above that electrical connectio...

Page 18: ...pump is still connected to the power supply 2 The pump control box is protected by a thermal safety In the event of overheating the motor stops automatically As soon as the temperature returns to norm...

Page 19: ...ch disconnected or fuse burnt 2 Impeller clogged 3 Stator winding burnt 1 check whether the head in use or power voltage are in compliance with requirements and adjust accordingly 2 Remove foreign mat...

Page 20: ...posto o l azienda incaricata per ulteriori informazioni sul metodo sicuro di smaltimento 3 1 LEGGERE TUTTE LE INFORMAZIONI PRIMA DI UTILIZZARE IL PRODOTTO 1 Mantenere in ordine l area di lavoro Il dis...

Page 21: ...ndo l attrezzo utilizzato con un estensione utilizzare soltanto estensioni concepite e previste per sopportare la corrente che alimenta l attrezzo 16 Fare sempre attenzione Guardare quello che si fa P...

Page 22: ...te una prolunga verificate che sia omologata Tenetela lontana da spigoli taglienti fonti di calore e combustibili 5 La presa mobile della prolunga deve essere di tipo 2 poli terra da 10 16A 250V secon...

Page 23: ...trata e in uscita f Attenzione se avete dubbi sulla sicurezza della pompa non fatene uso 4 1 Disimballagio 4 1 1 Controllare la pompa 1 Rimuovere il prodotto dal suo imballaggio e controllare che l at...

Page 24: ...monofase 220 240 V sono questi i valori limite consentito 50 60Hz la fluttuazione di tensione sia entro 0 94 1 06 volte il valore nominale 3 Evitare il contatto tra l alimentazione e il liquido da po...

Page 25: ...un mattone 4 Ispezionare l albero della pompa il quale dovrebbe essere libero di ruotare 5 La pompa pu essere installata sia con tubi in metallo che possono essere utilizzati per sostenere la pompa c...

Page 26: ...ad uso domestico industriale o agricolo per aspirare acque chiare con particelle in sospensione inferiori a 0 2mm o 0 5mm ved Caratteristiche 2 La pompa totalmente sommergibile la profondit di immersi...

Page 27: ...mente i seguenti componento la condizione dei cavi e anelli soprattutto il loro collegamento 6 2 Ricerca guasti Non tentare mai di smontare la pompa In caso di necessita fare controllare la pompa da u...

Page 28: ...chiave o fuori dalla portata dei bambini 6 5 Smaltimento Non gettare la pompa con i rifiuti domestici non gettare nell ambiente Portare la pompa in un centro di rifiuti o di raccolta o chiedere consig...

Page 29: ...xample IT Fig 2 Esempio di installazione 1 Alimentation principale 2 Bo tier de contr le 3 Tuyau de refoulement 4 Vanne 5 Support pompe 6 Enceinte de protection de la pompe 7 Sonde sup rieure niveau d...

Page 30: ...turbines 19 turbines 14 turbines Capacit de refoulement maxi Max Delivery capacity Capacit di scarico 4800 l h 3000 l h 1800 l h 4900 l h 4800 l h 4800 l h Pression maxi Max pressure Pressione max 6 7...

Reviews: