22
It’s possible at any time to set up again the factory parameters by resetting the card.
It’s sufficient to reset the card :
- Disconnect power to the electronic card.
- Press the learning- button and hold it pressed while you are giving tension to the electronic
card. The three LEDs flash once, after which they will remain lit.
- Hold the button pressed until the red LED turns off.
- Release the button.
After this operation must be carried out the settings again.
PROBLEMS
CAUSE
SOLUTIONS
At the instant of the switching on of the control unit all the
led (red, yellow, green) do not switch on for 1 second
- Power supply absent
- The plug is not inserted
- The connection to the electric net is absent
- The safety device has intervened
- Wait that it is reset
- Insert the plug
- Check the connections
- Check the connections and reset the device
The red led keep on blinking
- Rain alarm active (wet)
- Rain sensor is breakdown
- Wind alarm active
- Wind sensor breakdown
- Wait that the atmospheric conditions get better and the 7
minutes for the automatic reset
- Check the correct installation of the sensor
- Check the wiring of the sensor
- Contact the technician installer to raise the wind alarm
threshold.
The sunshade does not automatically open
- Slow external luminosity (green led turned off or with slow
blinking)
- Motor of the sunshade not working (green led turned off)
- Control unit not functioning
- Open manually the sunshade
- Check the correct installation of the luminosity sensor and
the threshold of automatic opening
- Check the requirements above.
The sunshade does not automatically close
- Elevated external luminosity (green led with quick blinking)
- Control unit not functioning (green led turned off)
- Control unit not working
- Close manually the sunshade.
- Check the correct installation of the sensor of luminosity
(for example far away from luminous sources, luminous
signs, etc.).
- Contact the technician-installator to DECREASE the
threshold of the light intensity for the automatic-opening.
- Contact the technician-installator
- Check the requirements above.
- Contact the technician-installator
After an alarm of wind or rain the sunshade does not reopen
itself
- Red led blinking
- Dip – switch 1 on OFF position
- The last movement made by the sunshade has been a
movement of closing
- The intensity of the light detected by the sensor is less
than the minimum threshold (threshold of closing) (green
led turned off)
- Motor of the sunshade not working
- Control unit not working.
- Wait for 7 minutes from the last recording of the alarm
- Put the dip – switch 1 on position ON
- The last order must be of opening
- Contact the technician-installator to INCREASE the
threshold of the light intensity for the automatic-opening.
- Contact the technician-installator.
- Contact the technician-installator.
I - GUIDE TO SOLVE PROBLEMS