20
Exclusion of light and rain sensor (only with dip 3 on ON )
ATTENTION: it is possible to exclude the light and rain sensors only on modality of
step by step from mechanical buttons.
The modality position and exclusion of the sensors has the goal to allow the user to control
manually the motion of the sunshade without the intervention of the sensors.
It is necessary to keep in mind some consideration about the security:
-
THE WIND SENSOR IS NEVER DISCONNECTED
- The rain sensor can be disconnected only if the dip 3 is positioned on ON. As previously
explained, the rain sensor rests inactive for a pre – determined time equally to 2 hours or
until you do not return in automatic modality.
MODALITY OF POSITIONING
During the normal functioning, any control of opening or closing brings the control unit in a
state of “positioning” in which the light sensor is excluded until the sunshade is not stopped
and the modality “exclusion of the sensors” is activated.
This device allows the user to choose easily the desired position of the sunshade.
Every control of movement unlock the count that restarts from zero in correspondence of
every fixed position (stop, open or close).
Once chosen the position, the sunshade can be locked pressing for more than 5 seconds
the stop button or the one opposite to the movement in course in case of open – close
controls.
If the modality of “exclusion of the sensors” is not activated after 5 seconds, the control unit
goes back again on automatic modality and the wind sensor is reactivated.
ATTENTION: in case of rain alarm active and dip – switch 3 positioned on ON, it
is possible to position the sunshade upon exclusion of the sensors
executed, before the movement, pressing for 5 seconds any button of
a learned transmitter. The exclusion is indicated by the fix switching of
the yellow led.
EXCLUSION OF THE SENSORS
Once put the sunshade on the desired position, pressing the opposite one in the case of
open – close control, for more than 5 seconds you enter on modality “exclusion of the
sensors”.
This modality excludes the light sensor, while the rain sensor is excluded for two
hours from the moment of the activation of the modality only if the dip – switch 3 is
positioned on ON.
This is because an user might want to keep the sunshade opened also in case of light rain.
ATTENTION: WHEN THE RAIN BECOMES DANGEROUS FOR THE STRUCTURE THE USER
MUST MANUALLY CLOSE THE SUNSHADE.
With the dip – switch 3 on OFF, the rain sensor is not disconnected.
RECONNECTION OF THE SENSORS
The sensors reactivate themselves after the pressure on a mechanical button or following to
an alarm.
An eventual replacing of the sunshade by the user must be executed in modality of
“positioning” and confirmed re – entering on modality “exclusion of the sensors”.
After two hours from the disconnection of the sensors the rain sensor reactivates itself
automatically (if the dip – switch 3 is on ON, otherwise is neither excluded).
The light sensor reactivates itself after a complete cycle of light.
This means that the luminous intensity must pass two thresholds before that the functioning
returns on automatic.
Examples:
- the light is faint (evening), but you want to maintain the door open or semi – open . In this
case it is sufficient disconnect the sensors. The control unit will return in automatic the
following evening (unless the sensors are manually reset).
- It drizzles and you want to open the door in any case; the sunshade is put on the desired
position previous exclusion of the sensors (as abovespecified), so by 5 seconds, the
exclusion of the sensors is confirmed. The sunshade will rest on this position until any
other control is given or at the expire of the two hours. After this, the control unit will reset
the rain sensor (the dip 3 must be positioned on ON).
SETTING OF THE “AUTOMATIC POSITION OF OPENING”
It is possible to modify the point in which the sunshade must stop on opening in case of
intervention of the light sensor.
This new position is called “automatic position of opening”.
To set this position it is important that no alarm is present.
1. Close the sunshades
2. Press and keep pressed the learning key until the led blinks quickly ( 7 seconds)
3. Release the key, the red led stops blinking
4. Press and keep pressed the opening wall button (only if the dip 2 is on ON); the sunshade
opens itself
5. After 4 seconds, a quick blink indicates that the control unit is entered in phase of
learning of the course, release the key.
6. Once reached the desired position, stop the sunshade and in this moment this position
will be memorized; the led stops blinking
If the sunshade gets the complete opening without the intervention of the user, the position
is deleted.
It is possible to modify the personalized position executing another learning at the same way
as just explained.
The reset of the control unit requires the deletion of the personalized position.
The personalized position can be reached with precision only and exclusively from the
position completely closed.
Moreover, during the normal functioning, the sunshade will stops itself on personalized
position only if the control of opening is given by the light sensor.
Any other order of opening takes the sunshade on the position of limit switch.
E - “CLOCK” MODALITY
The clock function is not useful neither with dead man walking modality nor with the
sensor light connected.
The clock modality is used in the situations in which you want open and close the sunshade
in a precise time and independently from the level of light that is present.
It is necessary that an external timer with a clean contact which remains closed for all the
time in which the sunshade must remain open and must open itself when the sunshade
must close itself.
The contact must be connected to the wall button “open”.
The wall buttons can be normally used if the function is not active, in contrary case any
order is ignored.
As usual, any sort of alarm provokes the closure of the sunshade that reopens itself
completely just it is finished, independently from the position of the automatic reopening dip
(dip 1).
F - LED OF SIGNALLING INPUTS AND OUTPUTS
The control unit is equipped with a series of LED for the signalling of the input and output
state, in order to make easy the operations of installation and the tests in case of failure of
the installation.
These led turn off themselves after 1 minute, the reactivation happens pressing two times
the learning key.
The meaning of the led is the following:
Led 1: wind sensor active
Led 2: rain sensor active
Led 3: light sensor present
Led 4: use of the internal memory
Led 5: reserved
Led 6: clock function active
Led 7: sunshade closed
Led 8: sunshade in opening
G