MINI TS control unit is equipped with a control panel, with which it is possible to monitor its
state of working.
The control panel is composed by three lighting warning lights (led):
- green warning light that indicates the intensity of the light;
- yellow warning light that indicates the functioning on setting “positioning” and “sensors
exclusion”;
- red warning light that indicates the alarm condition.
By these luminous indicators, it is possible to verify the correct functioning of the control unit
and identify the possible malfunctioning.
When voltage is given to the control unit, all the three indicators led will rest lighted up for one
second, then they will execute 3 blinking.
After few seconds, if the sensor of the luminous intensity is present, the green led will start to
blink in a different way according to the intensity of the light registered.
With this led it is quite possible to execute the regulation of the luminous intensity for the
automatic opening of the sunshade.
In the case in which a condition of alarm is present (wind or rain), the red led will start to blink
for the complete period of alarm (about 7 min.).
The yellow led indicates the functioning of the device on positioning mode and sensor exclusion
according to the way in which it blinks.
A - ELECTRICAL CONNECTIONS
B - CONTROL PANEL
Wind
Sensor
Rain
Sensor
External Power
Supply 12 Vac / dc
for heater
Light
Sensor
Connections Wind Sensor (ACG2275)
-
WHITE
cable on input
nr. 1
terminal board MINI TS.
-
GREEN
cable on input
nr. 4
terminal board MINI TS.
Connections Light Sensor (ACG2270)
- Connect the
terminal 1
of the light sensor to the
terminal 1
of the MINI TS control unit.
- Connect the
terminal 2
of the light sensor to the
terminal 7
of the MINI TS control unit.
Connections Rain Sensor (ACG2271)
- Connect the
terminal 3
of the rain sensor to the
terminal 1
of the MINI TS control unit.
- Connect the
terminal 4
of the rain sensor to the
terminal 10
of the MINI TS control unit.
- Connect to the terminal boards 1 and 2 of the rain sensor a voltage of 12-24 Vac/dc to
supply the heater
(not indispensable).
Connections Wind/Light sensor (ACG2276)
-
WHITE
and
BLUE
cable on input
nr. 1
terminal board MINI TS.
-
GREEN
cable on input
nr. 4
terminal board MINI TS.
-
YELLOW
cable on input
nr. 7
terminal board MINI TS.
WIND SENSORS
LIGHT SENSOR
ACG2270
RAIN SENSOR
ACG2271
ACG2275
ACG2276
G
B
Summary of Contents for ACG2265