16
The MINI TS control panel is a universal apparatus designed to manage sunshade activation
and control in a simple and complete manner and to meet any kind of requirement. This
product controls 1-phase 230V motors up to a power of 500W (max)
The logic of the MINI TS program offers the possibility of managing:
- wind speed detection
- light power
- rain detection
making if possible to open and/or close the sunshade in a completely automatic manner,
depending on current weather conditions.
CAUTION: DO NOT INSTALL THE CONTROL PANEL UNLESS YOU HAVE READ THE
INSTRUCTIONS FIRST!!!
INSTALLATION
Dangerous voltage is applied to some point of the electrical card: installation and setting of
control panel must be performed by trained personnel only.
A safety device should be installed to ensure disconnection of the control unit from the main
supply during maintenance operations.
Such feature can be obtained through an approved thermal breaker, two pole, adequate to
the current demand of the motor as installed.
Use conductors of approved type for the power circuit, with adequate section for the current
demand of the motor as installed.
TECHNICAL DATA
MINI TS
Supply voltage
230 Vac +10% - 15%
Motor outlet
230 Vac 500W MAX cos
ϕ
> 0,8
Card consumption
3W MAX
excluding accessories and utilities
Work schedule of the motor
7 minutes
Stand by time following wind alarm
7 minutes
Operating temperature
-10°C ÷ +60°C
Protection Grade
IP54
LED Diagnostics
They are activated for one minute after the
ignition, then they turn off. To reactivate
them, press 2 times for learning-button.
Connection Commands
Connect Open and Close buttons to terminals 1, 2, 3 following the scheme and trying to keep strictly a certain distance from the power.
At the same terminals you can also connect the RIB-twochannel radio receiver (code ACG5052).
Led Learning / Alarm
Learning Key
Trimmer for the regulation
of the wind alarm threshold
Power 230Vac 50 Hz
Do not connect directly the card to
the electric system but provide a
device that can ensure the omnipole
disconnection of the electronic card’s
supply.
Dip - switch
Jumper Selection Light-Intensity
Led Manual
Mode
Led External Light
detected
G
B
Summary of Contents for ACG2265
Page 30: ...30 NOTES ...