Preparing your HD-7000 or HD-6500 for the APES System:
Unplug HD-7000 or HD-6500 from outlet! Hazardous voltage inside! Crush hazard! Keep
hands away from moving parts!
Unplug foot pedal and store (The APES System has a foot pedal attached). See Figure B.
Using a Philips screwdriver rotate
counter clockwise. See Figure A. Only ¼ turn
is needed. Newer ONYX punches have two hex screws that need to be removed, one is located
in the same location as the safety screw shown in Figure A, the other is located on the left side of
the top cover.
the
Safety Screw
Raise the lid on your HD punch and remove the Paper Stop Assembly by first, removing the
nylock nut (use 7/16” wrench, not included) and then the paper stop nut located under the cover.
The paper stop and knob can now be removed from the front of the cover. See Figure B.
Re-assemble the Paper Stop into one piece and Store.
Close the lid and REPLACE the SAFETY SCREW to its locked position.
Your APES System came with two required Interface Blocks (Figure C page 8) that are 9” long by
¾” square, and four ¼-20 X 1-1/4” socket head cap screws and an allen wrench and torx wrench.
On each side of the punch, locate the two top most allen screws (or torx screws) and remove
(use the short side of the wrench for leverage) by turning counter clockwise.
6500/7000
7
Figure A
Figure B