O P E R A T I O N
Web Control Panel Operation
350-8794 V1.1
Linx DVI 8x8 Matix Switcher User’s Guide
25
. . . . .
Input Names
- Displays the names assigned using the
Configuration
tab to the eight inputs.
CONFIGURATION
. . . . . . . . .
TAB
The
Configuration
tab is used to name inputs and outputs and to set
EDID parameters.
Figure 3-10
Configuration Tab
Input Number
- Select an input number from the drop-down list.
Input Name
- To name or rename an input, type the desired name and
press
ENTER
.
Input EDID Assignment
- Select between a
Dynamic
EDID,
determined by the output EDID, or select a
Fixed
EDID from the drop-
down list. EDID assignment corresponds to the
EDIDMode
command.
See
EDID Control
in
Chapter 1
for more information.
Priority Rule
- When dynamic EDID is selected for an input routed to
multiple outputs, the priority rule determines which output EDID will be
used. The priority can be the output with the lowest resolution or the
lowest numbered output.
Output Number
- Select an output number from the drop-down list.
Output Name
- To name or rename an output, type the desired name
and press
ENTER
.
Note
Control-Z may be used to undo a single operation
only: either a loaded preset or route one input to all
outputs (right mouse click). The mouse cursor must
be placed within the routing matrix borders.