Application
Standard Roll Feed
2-11
DOK-SUPPL*-BTV04*ELW**-AW01-EN-P
In single step set-up mode a new start signal must come after every step.
If “operating mode select” F2 for automatic mode has been selected, then
the following appears:
Operating mode selection
F1 = feed leads / single
F2 = feed leads / continuous
F3 = press leads / single
F4 = press leads / continuous
Using keys F1 to F4 it is now possible to select various operating mode
combinations (feed leads, press leads, press single hub and press con-
tinuous run). After actuating the relevant key, the required program is
transmitted into the ELC and a message that states that the transmission
is completed comes after about five seconds.
Note:
For the transmitted programs to work in set-up and automatic
modes and for the operating mode display to be correct on the
BTV, task3 of the ELC in block number 0035 must be re-
leased.
Parameter AA00 = XXXX 0035 X
F2 Current operating mode
If „Operating mode“ has been selected with F2, then the currently pro-
grammed operating mode selected appears, as is shown below:
Current operating mode
automatic mode
press single hub
feed leads
Note:
To correctly display the operating mode, markers 40 to 46 are
processed in task3. The commands for this are automatically
sent with the operating mode.
Summary of Contents for Mannesmann DKC21.3
Page 1: ...Application DOK SUPPL BTV04 ELW AW01 EN P DKC21 3 for Roll Feeds with ELC and BTV04 ...
Page 6: ...1 2 Introduction Application DOK SUPPL BTV04 ELW AW01 EN P ...
Page 32: ...2 26 Standard Roll Feed Application DOK SUPPL BTV04 ELW AW01 EN P ...
Page 36: ...3 4 Terminal diagrams Application DOK SUPPL BTV04 ELW AW01 EN P ...
Page 37: ......