2-18
Standard Roll Feed
Application
DOK-SUPPL*-BTV04*ELW**-AW01-EN-P
AA00 Tasks 2 & 3
XXXX 0035 X
number of commands in task3 per NC cycle
task 3 _ start set
if ‚0000‘ here, then task 3 is not switched on
task 2 – start set
AA05 Electrical Ventilating
12 34
output: electrical ventilating inactive
Input: electrical ventilating active
If search pins are used, then the function “electrical ven-
tilating” can be activated here via an input.
(See ELC documentation).
In preparation.
AA07 Measuring wheel mode
01
Input „activate measuring wheel“
Input status = 0 control via motor encoder
Input status = 1 control via measuring wheel encoder
00 = not input programmed (measuring wheel is auto-
matic - mode always active is this is programmed in pa-
rameter A100.)
B000 Display
1 1
reserved
Language
0 = Germany
1 = English
2 = French
(in preparation)
3 = Spanish
(in preparation)
4 = Italian
(in preparation)