Application
Standard Roll Feed
2-3
DOK-SUPPL*-BTV04*ELW**-AW01-EN-P
0015 APE 0 0000000000
outputs (press) switched off
0016 JMP 0009
unconditional jump to block number 0009
0017 NOP
0018 NOP
0019 NOP
0020 BAC 0004 +0000 00010
item counter
0021 APE 0 0000000000
outputs (press) switched off
0022 NOP
0023 NOP
0024 NOP
0025 JST 0000
block jump with stop
Application-related program changes can be inserted into the empty lines.
Note:
The commands APE, PSI and BAC must be set in the block
numbers indicated in the program example as otherwise the
BTV program will not function.
In the programming examples above, Output 1 (X210/Pin 21) is used to
start the press. The feed range is transmitted via Input 1 (X210/Pin 7).
The program cycle is interrupted via Input 2 (X210/Pin 8). Using the cycle
interrupt, the program flow can be stopped at the current location, even if
the programmed piece count has not yet been reached. As soon as this
"on" signal (X210/Pin 8) goes back to zero, the program continues (with-
out a start command) from the same place it was stopped.