![Rexnord Falk Quadrive A Series Owner'S Manual Download Page 39](http://html1.mh-extra.com/html/rexnord/falk-quadrive-a-series/falk-quadrive-a-series_owners-manual_1449464039.webp)
Rexnord
378-206
3001 W. Canal St., Milwaukee, WI 53208-4200 USA
January 2019
Telephone:
414-342-3131
Fax:
414-937-4359
www.rexnord.com
Supersedes 07-15
(PN-212395)
Falk Quadrive Shaft-Mounted Drives Model A
•
Appendix E
Sizes 5407-5608
(Page 39 of 53)
2 . Coat all pipe threads of kitted parts with Permatex #3 or
equivalent sealant .
3 . Assemble kitted parts to drive as illustrated in Figure 2
and then secure the standpipe with an external support
to maintain its vertical position .
4 . Carefully measure Dimension X as illustrated in Figure 2 .
5 . From Table 1:
X + A equals oil level “Full” mark .
X + B equals oil level “Low” mark .
X + C equals dipstick length .
6 . Scribe Dimensions X + A and X + B on the dipstick as
illustrated in Figure 1 . Make measurements from the felt
pad in the dipstick cap .
7 . Lightly chisel permanent oil level marks on the scribed
lines and cut the dipstick to the length marked . File end
of dipstick smooth .
8 . Install magnetic drain plug (furnished) in oil drain
location .
9 . Remove the oil filler plug . Add oil until the oil level
reaches the “Full” mark on the dipstick . Coat the filler
plug (not vented) with Permatex #3 or equivalent sealant
and replace it .
10 . Filler plug must always be removed to relieve
entrapped air before checking oil level .